Duct units

Thanks to their exceptionally slim casing, they are suitable even for low-ceiling spaces. The automatic ESP adjustment function ensures consistent comfort in cooling and heating, regardless of the installation length.

DUCTED UNITS

AUX-C-(18/24/30/36/42/48/60)CAD

COMFORTABLE AND EFFICIENT COOLING

Even in large spaces

Efficient and hidden units, giving the greatest freedom in designing the system. Thanks to the extremely flat design, the casing will fit even in low ceiling spaces. Adjustable static pressure up to 160 Pa allows the using long ventilation ducts and the automatic ESP adjustment function guarantees comfortable cooling and heating at all times, regardless of the length of the ducts.

BUILD-IN CONDENSATE PUMP

Lifting height up to 70 cm

The AUX duct unit can be additionally equipped with a condensate pump, which allows to drain the water condensate up to 70 cm above the drain pan level.

Flexible system design

Even over long distances

Adjustable static pressure from 0 to 160Pa allows greater flexibility in designing the installation – it enables using long ventilation ducts.

FLEXIBLE INSTALLATION

Two air intake options

The design of the duct unit allows two ways of mounting the air inlet, giving greater freedom in designing the system. As standard, the air inlet is located at the back of the unit. If the room arrangement requires it, the air can also be taken in via the lower air inlet (optional).

Automatic ESP adjustment

Comfortable conditions and low noise level

The Automatic Static Pressure Control (ESP) function provides comfortable room conditions with low noise levels. The fan speed and the amount of supplied air are automatically adjusted to the length of the ventilation duct, so as to provide a constant air flow regardless of the length of the pipework.

HIGH-QUALITY INVERTER COMPRESSOR

Guarantee of energy efficiency and reliability

The inverter rotary compressor of AUX air conditioners guarantees reliable and efficient operation of the devices as well as the highest energy efficiency parameters. It also provides low operating costs and a low level of noise. Durable and high-quality materials of the compressor guarantee its long and failure-free operation.

Anti-corrosion casing

Longer life and better aesthetics

The casing of the outdoor unit has been covered with a number of protective layers, protecting it against insects, rodents, moisture, dust and fire. It guarantees a long lifespan of the device and an better aesthetics after many years of exposure to adverse weather conditions.

OPTIMISED PIPING DESIGN

Improving cooling capacity

The design provides enhanced cooling by separating the refrigerant inlet and outlet, which not only increases the cooling capacity but also ensures more stable and efficient operation of the system, resulting in consistent comfort throughout the room.

INTELLIGENT DEFROSTING

Effective operation at low ambient temperatures

The air conditioner activates the defrosting mode only when necessary and only for the time needed to defrost the heat exchanger, which allows the unit to operate almost continuously in heating mode. The intelligent defrosting system used in AUX air conditioners improves the energy efficiency of the devices by 5% and increases the heating efficiency as much as 20% at low ambient temperatures.

A wide range of operation

Reliable operation even in adverse weather conditions

AUX commercial air conditioning systems are characterised by reliable, stable operation even in extreme ambient temperatures. Owing to the use of modern technologies and high-quality components, AUX devices operate in a wide range of outdoor temperatures, i.e. from -15°C to 52°C in cooling mode and from -22°C to 24°C in heating mode, providing a high level of comfort in the room in all the seasons of the year.

AUTOMATIC RESTART

Memory retention during power failure

In the event of a power failure, the device records the last settings and restarts after resuming the power supply, automatically restoring the previously set operating mode.

Outdoor unit drip tray heater​

Efficient operation in heating mode​

Outdoor units of AUX commercial air conditioner series are equipped with a drip tray heaters, which allow the devices to operate efficiently in heating mode even in severe frosts, preventing the heat exchanger from icing.

REFRIGERANT R32

Eco-friendly, highly efficient, and safe

All AUX air conditioning units operate using the latest eco-friendly refrigerant R32, which, compared to the commonly used R410A, offers higher efficiency and a lower global warming potential. It also does not deplete the ozone layer.

HIGH ENERGY EFFICIENCY

Guaranteed energy savings and reliability

The inverter rotary compressor used in AUX air conditioners ensures reliable and efficient operation, delivering top energy efficiency. It also provides low operating costs and minimal noise. Durable, high-quality materials in the compressor’s construction guarantee long-lasting, trouble-free performance.

TECHNICAL DATA

AUX-C-(12/18/24/30)CAD

Model AUX-C-12CAD AUX-C-18CAD AUX-C-24CAD AUX-C-30CAD
Cooling capacity [kW] 3,52 (1,35 – 4,40) 5,28 (1,53 – 5,60) 7,03 (2,16 – 8,20) 8,65 (2,49 – 9,20)
[Btu/h] 12000 (4600 – 15000) 18000 (5200 – 19100) 24000 (7400 – 28000) 29500 (8490 – 31390)
Heating capacity [kW] 3,81 (1,24 – 5,30) 5,60 (1,40 – 6,20) 7,91 (1,98 – 9,30) 9,20 (2,86 – 9,60)
[Btu/h] 13000 (4200 – 18100) 19100 (4800 – 21200) 27000 (6800 – 31700) 31390 (9760 – 32760)
Power consumption Cooling [W] 1,03 (0,26 – 1,60) 1,55 (0,47 – 2,30) 2,17 (0,67 – 3,30) 2,10 (0,67 – 3,30)
Heating [W] 1,02 (0,19 – 1,51) 1,51 (0,46 – 2,25) 2,13 (0,65 – 3,30) 2,40 (0,67 – 3,30)
Current consumption Cooling [A] 4,48 (1,13 – 6,96) 6,73 (2,04 – 10,00) 9,43 (2,91 – 14,35) 11,09 (3,09 – 14,35)
Heating [A] 4,43 (0,83 – 6,57) 6,48 (2,00 – 9,78) 9,26 (2,83 – 14,35) 10,43 (2,91 – 14,35)
EER / COP 3,41 / 3,73 3,40 / 3,76 3,24 / 3,71 3,39 / 3,83
SEER / SCOP 6,10 / 4,00 6,10 / 4,00 6,10 / 4,00 6,10 / 4,00
Energy efficiency class Cooling A++ A++ A++ A++
Heating A+ A+ A+ A+
lIndoor unit AUX-C-12CAD/I AUX-C-18CAD/I AUX-C-24CAD/I AUX-C-30CAD/I
Power supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Fan motor power [W] 120 120 200 200
Fan speed (high / medium / low) [rpm] 980/880/800 1180/1050/930 1200/1065/960 1350/1245/1110
Airflow (high / medium / low) [m3/h] 720/600/500 900/750/630 1400/1190/980 1600/1400/1100
Sound pressure level (high / medium / low) [dB(A)] 37/34/32 44/41/37 43/41/39 46/44/41
Sound power level [dB(A)] 54 55 57
Indoor unit dimensions [mm] 700 x 700 x 245 700 x 700 x 245 1000 x 700 x 245 1000 x 700 x 245
Indoor unit weight (net) [kg] 21,0 22,0 32,0 32,0
Outdoor unit AUX-C-12CAO AUX-C-18CAO AUX-C-24CAO AUX-C-30CAO
Power supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Compressor type rotary rotary rotary rotary
Airflow [m3/h] 2000 2600 4200 4200
Sound pressure level [dB(A)] 54 55 58 58
Sound power level [dB(A)] 64 65 68 68
Outdoor unit dimensions [mm] 709 x 283 x 536 785 x 300 x 555 900 x 350 x 700 900 x 350 x 700
Outdoor unit weight (net) [kg] 23,0 29,0 43,0 50,0
Refrigerant Type R32 R32 R32 R32
Factory charge [kg] 0,78 1,03 1,45 1,65
Pipe connections (diameter) Liquid [mm(inches)] 6,35 (1/4) 6,35 (1/4) 9,52 (3/8) 9,52 (3/8)
Gas [mm(inches)] 12,70 (1/2) 12,70 (1/2) 15,88 (5/8) 15,88 (5/8)
Condensate [mm(inches)] DN20 (R3/4) DN20 (R3/4) DN20 (R3/4) DN20 (R3/4)
Maximum pipe length [m] 25 30 50 50
Maximum height difference [m] 10 20 25 25
Outdoor unit operation (ambient temperature) Cooling [°C] -15~52 -15~52 -15~52 -15~52
Heating [°C] -22~24 -22~24 -22~24 -22~24
Operating temperature range [°C] 16~32 16~32 16~32 16~32

 We reserve the right for errors in descriptions, appearance, function, technical parameters, and dimensional drawings resulting from the continuous improvement of our devices.

TECHNICAL DATA

AUX-C-(36/42/48/60)CAD

Model AUX-C-36CAD AUX-C-42CAD AUX-C-48CAD AUX-C-60CAD
Cooling capacity [kW] 10,55 (2,90 – 11,00) 12,10 (2,90 – 13,00) 14,00 (4,76 – 16,60) 16,00 (4,76 – 17,50)
[Btu/h] 36000 (9800 – 37500) 42000 (9800 – 44300) 48000 (16241 – 56639) 55000 (16241 – 59710)
Heating capacity [kW] 11,15 (2,60 – 11,50) 13,50 (2,60 – 14,00) 16,00 (4,78 – 18,40) 17,00 (4,78 – 18,50)
[Btu/h] 38000 (8800 – 39200) 46000 (8800 – 47700) 55000 (16309 – 62781) 58000 (16308 – 63122)
Power consumption Cooling [W] 3,50 (0,71 – 4,20) 3,90 (0,71 – 4,50) 4,80 (1,71 – 5,90) 5,60 (1,71 – 6,85)
Heating [W] 3,00 (0,47 – 3,70) 3,50 (0,47 – 4,20) 4,50 (1,71 – 6,05) 4,80 (1,71 – 7,00)
Current consumption Cooling [A] 15,80 (3,20 – 19,50) 18,00 (3,20 – 20,00) 8,40 (1,50 – 12,00) 10,00 (1,50 – 12,00)
Heating [A] 13,00 (2,43 – 16,00) 16,00 (2,43 – 18,50) 8,00 (1,50 – 12,00) 8,00 (1,50 – 12,00)
EER / COP 3,01 / 3,72 3,10 / 3,86 2,92 / 3,56 2,86 / 3,54
SEER / SCOP 6,10 / 4,00 … / … … / … … / …
Energy efficiency class Cooling A++ A++ A++ A++
Heating A+ A+ A+ A+
Indoor unit AUX-C-36CAO AUX-C-42CAO AUX-C-48CAO AUX-C-60CAO
Power supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Fan motor power [W] 300 300 300 300
Fan speed (high / medium / low) [rpm] 1245/1170/1095 1245/1170/1095 1425/1305/1200 1425/1305/1200
Airflow rate (high / medium / low) [m3/h] 2040/1800/1600 2040/1800/1600 2300/2000/1700 2300/2000/1700
Sound pressure level (high / medium / low) [dB(A)] 44/42/41 44/42/41 52/45/43 52/47/45
Sound power level [dB(A)] 55 55 64 64
Indoor unit dimensions [mm] 1400 x 700 x 245 1400 x 700 x 245 1400 x 700 x 245 1400 x 700 x 245
Indoor unit weight (net) [kg] 38,0 38,0 38,0 38,0
Outdoor unit AUX-C-36CAO AUX-C-42CAO AUX-C-48CAO AUX-C-60CAO
Power supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 380-415, 50, 3 380-415, 50, 3
Compressor type rotary rotary rotary rotary
Airflow rate [m3/h] 4000 4000 7200 7200
Sound pressure level [dB(A)] 59 60 60 60
Sound power level [dB(A)] 69 70 70 70
Outdoor unit dimensions [mm] 970 x 395 x 805 970 x 395 x 805 940 x 370 x 1325 940 x 370 x 1325
Outdoor unit weight (net) [kg] 61,0 61,0 81,0 85,0
Refrigerant Type R32 R32 R32 R32
Factory charge [kg] 2,75 2,75 2,70 3,05
Pipe connections (diameter) Liquid [mm(inch)] 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8)
Gas [mm(inch)] 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8)
Condensate [mm(inch)] DN20 (R3/4) DN20 (R3/4) DN20 (R3/4) DN20 (R3/4)
Maximum piping length [m] 65 65 65 65
Maximum height difference [m] 30 30 30 30
Outdoor unit operation (ambient temperature) Cooling [°C] -15~52 -15~52 -15~52 -15~52
Heating [°C] -22~24 -22~24 -22~24 -22~24
Operating temperature range [°C] 16~32 16~32 16~32 16~32

 We reserve the right for errors in descriptions, appearance, function, technical parameters, and dimensional drawings resulting from the continuous improvement of our devices.

FEATURES AND FUNCTIONS

Long term
filter
R32
refrigerant
Wired
controller
24-hour
timer
Optional wireless controller
Cooling
mode
Fast cooling / heating
Heating
mode
AUTO
mode
Fan
mode
Dehumidifying mode
Anti-Cold-Air function
Night
mode
I FEEL
function
TURBO
mode
Inverter
technology
Intelligent
defrosting function
Hydrophilic aluminum blades
Automatic
restart
Super
EMC
Cooling in low temperatures
We value your privacy