Floor/ceiling units

Efficient, universal units of compact size and flexible installation options are perfect for any space.

Floor / ceiling units

CAF series

AUX-C-(18/24/36/42/48/60)CAF

Universal mounting
and ultra-slim design

Only 235 mm high

The design of the floor-ceiling unit allows you to adjust the method of its installation to the arrangement of the room – the device can be mounted both vertically (on the floor by the wall) and horizontally (suspended over the ceiling). It does not require construction of any casing covering it – it will fit well in rooms without a suspended ceiling. The extremely low height of the unit – only 235 mm – allows it to be installed even in limited spaces.

INNOVATIVE FAN

Quiet and comfortable air flow

Floor-ceiling units are equipped with a 3-step fan speed adjustment, which allows the airflow level to be adjusted to the height of the room. The innovative swirl fan provides a larger volume of air, while reducing the noise level.

UNIVERSAL, TIMELESS DESIGN

The universal, timeless and the compact design of the AUX floor and ceiling units make them suitable for use in a wide variety of rooms, from commercial spaces – shops, restaurants and offices – to detached houses and apartments.

TECHNICAL DATA

AUX-C-(18/24/36)CAF

Model AUX-C-18CAF AUX-C-24CAF AUX-C-36CAF
Cooling capacity [kW] 5,30 (1,60 – 6,00) 7,03 (2,16 – 8,20) 10,55 (2,90 – 11,50)
[Btu/h] 18000 (5500 – 20500) 24000 (7400 – 28000) 36000 (9900 – 39200)
Heating capacity [kW] 5,70 (1,40 – 7,20) 7,62 (1,98 – 9,30) 11,15 (2,60 – 12,00)
[Btu/h] 19450 (4800 – 24600) 26000 (6800 – 31700) 38000 (8900 – 40900)
Power supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Power consumption Cooling [W] 1,55 (0,48 – 2,30) 2,15 (0,67 – 3,30) 3,30 (0,71 – 4,20)
Heating [W] 1,52 (0,47 – 2,40) 2,05 (0,65 – 3,30) 3,00 (0,47 – 3,70)
Current consumption Cooling [A] 6,74 (2,09 – 10,00) 9,34 (2,91 – 14,35) 14,50 (3,20 – 19,50)
Heating [A] 6,61 (2,04 – 10,43) 8,91 (2,83 – 14,35) 13,00 (2,43 – 16,00)
EER / COP 3,42 / 3,75 3,27 / 3,72 3,20 / 3,72
SEER / SCOP 6,10 / 4,00 6,10 / 4,00 6,10 / 4,00
Energy efficiency class Cooling A++ A++ A++
Heating A+ A+ A+
Indoor Unit AUX-C-18CAF/I AUX-C-24CAF/I AUX-C-36CAF/I
Fan motor power [W] 40 70 120
Fan speed (high / medium / low) [rpm] 950/790/690 1000/860/760 1250/1080/900
Airflow (high / medium / low) [m³/h] 900/720/600 1230/1020/840 2040/1740/1440
Sound pressure level (high / medium / low) [dB(A)] 40/35/33 42/38/35 50/46/41
Sound power level [dB(A)] 51 52 62
Indoor unit dimensions [mm] 1000 x 690 x 235 1280 x 690 x 235 1600 x 690 x 235
Indoor unit weight (net) [kg] 28,0 34,0 39,5
Outdoor Unit AUX-C-18CAO AUX-C-24CAO AUX-C-36CAO
Compressor type Rotary Rotary Rotary
Airflow [m³/h] 2600 4200 4000
Sound pressure level [dB(A)] 55 58 59
Sound power level [dB(A)] 65 68 69
Outdoor unit dimensions [mm] 785 x 300 x 555 900 x 350 x 700 970 x 395 x 805
Outdoor unit weight (net) [kg] 29,0 43,0 61,0
Refrigerant Type R32 R32 R32
Factory charge [kg] 1,03 1,45 2,75
Pipe connections (diameter) Liquid [mm (inch)] 6,35 (1/4) 9,52 (3/8) 9,52 (3/8)
Gas [mm (inch)] 12,70 (1/2) 15,88 (5/8) 15,88 (5/8)
Condensate [mm (inch)] DN20 (R3/4) DN20 (R3/4) DN20 (R3/4)
Maximum pipe length [m] 30 50 65
Maximum height difference [m] 20 25 30
Outdoor unit operation
(ambient temperature)
Cooling [°C] -15~52 -15~52 -15~52
Heating [°C] -22~24 -22~24 -22~24
Operating temperature range [°C] 16~32 16~32 16~32

TECHNICAL DATA

AUX-C-(42/48/60)CAF

Model AUX-C-42CAF AUX-C-48CAF AUX-C-60CAF
Cooling capacity [kW] 12,10 (2,90 – 12,50) 14,00 (4,76 – 14,50) 16,00 (4,76 – 17,50)
[Btu/h] 42000 (9800 – 42600) 48000 (16241 – 49474) 55000 (16241 – 59710)
Heating capacity [kW] 13,50 (2,60 – 14,50) 16,00 (4,78 – 16,50) 17,00 (4,78 – 18,50)
[Btu/h] 46000 (8800 – 49400) 54600 (16309 – 56298) 58000 (16309 – 63122)
Power supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Power consumption Cooling [W] 3,80 (0,71 – 4,50) 5,00 (1,71 – 5,90) 5,80 (1,71 – 6,85)
Heating [W] 3,50 (0,47 – 4,20) 5,10 (1,71 – 6,05) 4,90 (1,71 – 7,00)
Current consumption Cooling [A] 17,00 (3,20 – 20,00) 8,80 (1,50 – 12,00) 10,50 (1,50 – 15,00)
Heating [A] 16,00 (2,43 – 18,50) 8,90 (1,50 – 12,00) 11,00 (1,50 – 15,00)
EER / COP 3,18 / 3,86 2,80 / 3,14 2,76 / 3,47
SEER / SCOP … / … … / … … / …
Energy efficiency class Cooling A++ A++ A++
Heating A+ A+ A+
Indoor unit AUX-C-42CAF/I AUX-C-48CAF/I AUX-C-60CAF/I
Fan motor power [W] 120 120 120
Fan speed (high / medium / low) [rpm] 1250/1080/900 1250/1080/900 1280/1100/920
Airflow (high / medium / low) [m³/h] 2040/1740/1440 2040/1740/1440 2160/1820/1480
Sound pressure level (high / medium / low) [dB(A)] 50/46/41 50/46/41 51/47/43
Sound power level [dB(A)] 62 62 63
Indoor unit dimensions [mm] 1600 x 690 x 235 1600 x 690 x 235 1600 x 690 x 235
Indoor unit weight (net) [kg] 39,5 40,0 41,0
Outdoor unit AUX-C-42CAO AUX-C-48CAO AUX-C-60CAO
Compressor type rotary rotary rotary
Airflow [m³/h] 4000 7200 7200
Sound pressure level [dB(A)] 60 60 60
Sound power level [dB(A)] 70 70 70
Outdoor unit dimensions [mm] 960 x 395 x 805 940 x 370 x 1325 940 x 370 x 1325
Outdoor unit weight (net) [kg] 61,0 81,0 85,0
Refrigerant Type R32 R32 R32
Factory charge [kg] 2,75 2,70 3,05
Pipe connections (diameter) Liquid [mm(inches)] 9,52 (3/8) 9,52 (3/8) 9,52 (3/8)
Gas [mm(inches)] 15,88 (5/8) 15,88 (5/8) 15,88 (5/8)
Condensate [mm(inches)] DN20 (R3/4) DN20 (R3/4) DN20 (R3/4)
Maximum pipe length [m] 30 50 65
Maximum height difference [m] 20 25 30
Outdoor unit operation
(outdoor temperature)
Cooling [°C] -15~52 -15~52 -15~52
Heating [°C] -22~24 -22~24 -22~24
Operating temperature range [°C] 16~32 16~32 16~32

FEATURES AND FUNCTIONS

Long term
filter
R32
refrigerant
Wireless
controller
24-hour
timer
Optional wired controller
Cooling
mode
Fast cooling / heating
Heating
mode
AUTO
mode
Fan
mode
Dehumidifying mode
Vertical louver movement
Anti-Cold-Air function
Night
mode
I FEEL
function
TURBO
mode
Inverter
technology
Intelligent
defrosting function
Hydrophilic aluminum blades
Automatic
restart
Super
EMC
Cooling in low temperatures

R32 REFRIGERANT

Ecological, highly effective, safe

All AUX air conditioning units of CAC series operate using the newest ecological refrigerant R32, which, comparing to the commonly used R410A refrigerant, is characterised by higher efficiency and a lower greenhouse effect. It also does not damage the ozone layer.

HIGH ENERGY EFFICIENCY

Guarantee of energy-saving operation

Owing to the use of a highly efficient DC inverter compressor, adjustable fan motor and advanced 180° sine wave vector control technology, commercial AUX systems achieve high energy efficiency parameters, providing reliable, efficient operation with low energy consumption. All CAC air conditioners are class A ++ in cooling and A + in heating mode.

A wide range of operation

Reliable operation even in adverse weather conditions

AUX commercial air conditioning systems are characterised by reliable, stable operation even in extreme ambient temperatures. Owing to the use of modern technologies and high-quality components, AUX devices operate in a wide range of outdoor temperatures, i.e. from -15°C to 52°C in cooling mode and from -22°C to 24°C in heating mode, providing a high level of comfort in the room in all the seasons of the year.

Anti-corrosion casing of the outdoor unit

Longer life and better aesthetics

The casing of the outdoor unit has been covered with a number of protective layers, protecting it against insects, rodents, moisture, dust and fire. It guarantees a long lifespan of the device and an better aesthetics after many years of exposure to adverse weather conditions.

INTELLIGENT DEFROSTING

Effective operation at low ambient temperatures

The air conditioner activates the defrosting mode only when necessary and only for the time needed to defrost the heat exchanger, which allows the unit to operate almost continuously in heating mode. The intelligent defrosting system used in AUX air conditioners improves the energy efficiency of the devices by 5% and increases the heating efficiency as much as 20% at low ambient temperatures.

AUTOMATIC RESTART

Setting memory in the event of a power failure

In the event of a power failure, the device records the last settings and restarts after resuming the power supply, automatically restoring the previously set operating mode.

Outdoor unit drip tray heater

Efficient operation in heating mode

Outdoor units of AUX commercial air conditioner series are equipped with a  drip tray heaters, which allow the devices to operate efficiently in heating mode even in severe frosts, preventing the heat exchanger from icing.

180 sine wave control

Smooth and efficient operation of the compressor

The DC inverter compressor uses 180° sine wave control. The solution makes the compressor motor run smoothly and the efficiency increases significantly.

Optimized piping design

Improving cooling capacity

The design provides additional cooling and increases the cooling capacity through separating the refrigerant inlet and outlet.

We value your privacy

The website uses cookies to provide its services in accordance with the Cookies Policy. You can specify the conditions for storing or accessing cookies in your browser.