Cassette units

Quiet and efficient AUX cassette units are an excellent choice for commercial interiors with suspended ceilings – such as offices, conference rooms, restaurants, and retail spaces. Thanks to 360° surround air distribution technology and the fast cooling/heating function, they can ensure comfortable conditions in every corner of the air-conditioned room

CASSETTE UNITS

AUX-C-(12/18/24/36/42/48/60)CAC

EFFICIENT AND COMFORTABLE COOLING

Maximum comfort indoors

Quiet and efficient AUX cassette units are perfect for commercial interiors with a suspended ceiling – offices, conference rooms, restaurants and commercial spaces. Thanks to the 360° circumferential airflow technology and the quick cooling / heating function, they can provide comfortable conditions in all the area of the room.

360° perimeter airflow

Effective air distribution

Thanks to its specially designed decorative panel, the AUX cassette air conditioner delivers 360° airflow for even cooling throughout the room. Corner outlets eliminate temperature differences, ensuring effective comfort even in large spaces.

BUILD-IN CONDENSATE PUMP

Lifting height up to 120 cm

The cassette unit comes with a condensate pump, allowing water to be drained up to 120 cm above the condensate tray level.

FRESH AIR INTAKE

Comfort and safety

The cassette unit’s casing includes a factory-cut opening for fresh air intake, allowing the device to supply fresh outdoor air into the room. Drawing in fresh air improves indoor air quality, ensuring the health and comfort of occupants. The optimised electrical box provides easy service access and high fire resistance.

HIGH-QUALITY INVERTER COMPRESSOR

Guarantee of energy efficiency and reliability

The inverter rotary compressor of AUX air conditioners guarantees reliable and efficient operation of the devices as well as the highest energy efficiency parameters. It also provides low operating costs and a low level of noise. Durable and high-quality materials of the compressor guarantee its long and failure-free operation.

REFRIGERANT R32

Eco-friendly, highly efficient, and safe

All AUX air conditioning units operate using the latest eco-friendly refrigerant R32, which, compared to the commonly used R410A, offers higher efficiency and a lower global warming potential. It also does not deplete the ozone layer.

HIGH ENERGY EFFICIENCY

Guaranteed energy savings and reliability

The inverter rotary compressor used in AUX air conditioners ensures reliable and efficient operation, delivering top energy efficiency. It also provides low operating costs and minimal noise. Durable, high-quality materials in the compressor’s construction guarantee long-lasting, trouble-free performance.

INTELLIGENT DEFROSTING

Effective operation at low ambient temperatures

The air conditioner activates the defrosting mode only when necessary and only for the time needed to defrost the heat exchanger, which allows the unit to operate almost continuously in heating mode. The intelligent defrosting system used in AUX air conditioners improves the energy efficiency of the devices by 5% and increases the heating efficiency as much as 20% at low ambient temperatures.

A wide range of operation

Reliable operation even in adverse weather conditions

AUX commercial air conditioning systems are characterised by reliable, stable operation even in extreme ambient temperatures. Owing to the use of modern technologies and high-quality components, AUX devices operate in a wide range of outdoor temperatures, i.e. from -15°C to 52°C in cooling mode and from -22°C to 24°C in heating mode, providing a high level of comfort in the room in all the seasons of the year.

Anti-corrosion casing

Longer life and better aesthetics

The casing of the outdoor unit has been covered with a number of protective layers, protecting it against insects, rodents, moisture, dust and fire. It guarantees a long lifespan of the device and an better aesthetics after many years of exposure to adverse weather conditions.

OPTIMISED PIPING DESIGN

Improving cooling capacity

The design provides enhanced cooling by separating the refrigerant inlet and outlet, which not only increases the cooling capacity but also ensures more stable and efficient operation of the system, resulting in consistent comfort throughout the room.

180 sine wave control

Smooth and efficient operation of the compressor

The DC inverter compressor uses 180° sine wave control. The solution makes the compressor motor run smoothly and the efficiency increases significantly.

Outdoor unit drip tray heater

Efficient operation in heating mode

Outdoor units of AUX commercial air conditioner series are equipped with a  drip tray heaters, which allow the devices to operate efficiently in heating mode even in severe frosts, preventing the heat exchanger from icing.

AUTOMATIC RESTART

Memory retention during power failure

In the event of a power failure, the device records the last settings and restarts after resuming the power supply, automatically restoring the previously set operating mode.

TECHNICAL DATA

AUX-C-(12/18/24)CAC

Model AUX-C-12CAC AUX-C-18CAC AUX-C-24CAC
Cooling Capacity [kW] 3,52 (1,35 – 4,40) 5,28 (1,53 – 5,60) 7,03 (2,16 – 8,20)
[Btu/h] 12000 (4600 – 15000) 18000 (5200 – 19100) 24000 (7400 – 28000)
Heating Capacity [kW] 3,81 (1,24 – 5,30) 5,60 (1,40 – 6,20) 7,91 (1,98 – 9,30)
[Btu/h] 13000 (4200 – 18100) 19100 (4800 – 21200) 27300 (6800 – 31700)
Power Consumption Cooling [W] 1,03 (0.26 – 1,60) 1,55 (0,47 – 2,30) 2,10 (0.67 – 3,30)
Heating [W] 1,02 (0,19 – 1,51) 1,51 (0,46 – 2,25) 2,13 (0,65 – 3,30)
Current Consumption Cooling [A] 4,48 (1,13- 6,96) 6,74 (2,04 – 10,00) 9,13 (2,91 – 14,35)
Heating [A] 4,43 (0,83 – 6,57) 6,57 (2,00 – 9,78) 9,26 (2,83 – 14,35)
EER / COP 3,41 / 3,73 3,41 / 3,71 3,35 / 3,71
SEER / SCOP 6,10 / 4,00 6,10 / 4,00 6,10 / 4,00
Energy Efficiency Class Cooling A++ A++ A++
Heating A+ A+ A+
Indoor Unit AUX-C-12CAC/I AUX-C-18CAC/I AUX-C-24CAC/I
Power Supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Decorative Panel AUX-P-01 AUX-P-01 AUX-P-02
Fan Motor Power [W] 30 30 100
Fan Speed (High / Medium / Low) [rpm] 720/660/530 840/720/660 580/530/470
Airflow (High / Medium / Low) [m³/h] 700/620/530 760/650/580 1500/1350/1200
Sound Pressure Level (High / Medium / Low) [dB(A)] 42/38/35 44/41/38 46/45/43
Sound Power Level [dB(A)] 52 56 56
Indoor Unit Dimensions [mm] 570 x 570 x 260 570 x 570 x 260 840 x 840 x 246
Indoor Unit Weight (Net) [kg] 15,5 15,5 26,0
Panel Dimensions [mm] 650 x 650 x 55 650 x 650 x 55 950 x 950 x 55
Panel Weight (Net) [kg] 2,2 2,2 5,3
Outdoor Unit AUX-C-12CAO AUX-C-18CAO AUX-C-24CAO
Power Supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Compressor Type Rotary Rotary Rotary
Airflow [m³/h] 2000 2600 4200
Sound Pressure Level [dB(A)] 54 55 58
Sound Power Level [dB(A)] 64 65 68
Outdoor Unit Dimensions [mm] 709 x 283 x 536 785 x 300 x 555 900 x 350 x 700
Outdoor Unit Weight (Net) [kg] 23,0 29,0 43,0
Refrigerant Type R32 R32 R32
Factory Charge [kg] 0,78 1,03 1,45
Pipe Connections (Diameter) Liquid [mm(in)] 6,35 (1/4) 6,35 (1/4) 9,52 (3/8)
Gas [mm(in)] 12,70 (1/2) 12,70 (1/2) 15,88 (5/8)
Condensate [mm(in)] DN20 (R3/4) DN20 (R3/4) DN20 (R3/4)
Max Piping Length [m] 25 30 50
Max Height Difference [m] 10 20 25
Outdoor Unit Operating Range (Ambient Temperature) Cooling [°C] -15~52 -15~52 -15~52
Heating [°C] -22~24 -22~24 -22~24
Operating Temperature Range [°C] 16~32 16~32 16~32

 We reserve the right for errors in descriptions, appearance, function, technical parameters, and dimensional drawings resulting from the continuous improvement of our devices.

TECHNICAL DATA

AUX-C-(36/42/48/60)CAC

Model AUX-C-36CAC AUX-C-42CAC AUX-C-48CAC AUX-C-60CAC
Cooling Capacity [kW] 10,55 (2,90 – 11,50) 12,10 (2,90 – 12,50) 14,00 (4,76 – 14,50) 16,00 (4,76 – 17,50)
[Btu/h] 36000 (9800 – 39200) 42000 (9800 – 42600) 48000 (16241 – 49474) 55000 (16241 – 59710)
Heating Capacity [kW] 11,15 (2,60 – 12,00) 13,50 (2,60 – 14,50) 16,00 (4,78 – 17,30) 17,00 (4,78 – 18,50)
[Btu/h] 38000 (8800 – 40900) 46000 (8800 – 49400) 55000 (16309 – 59028) 58000 (16308 – 63122)
Power Consumption Cooling [W] 3,30 (0,71 – 4,20) 3,80 (0,71 – 4,50) 4,65 (1,71 – 5,90) 5,25 (1,71 – 6,85)
Heating [W] 3,00 (0,47 – 3,70) 3,50 (0,47 – 4,20) 4,58 (1,71 – 6,05) 5,05 (1,71 – 7,00)
Current Consumption Cooling [A] 14,50 (3,20 – 19,50) 17,00 (3,20 – 20,00) 8,10 (1,50 – 12,00) 9,00 (1,50 -12,00)
Heating [A] 13,00 (2,43 – 16,00) 16,00 (2,43 – 18,50) 8,00 (1,50 – 12,00) 8,50 (1,50 – 12,00)
EER / COP 3,20 / 3,72 3,18 / 3,86 3,01 / 3,49 3,05 / 3,37
SEER / SCOP 6,10 / 4,00 … / … … / … … / …
Energy Efficiency Class Cooling A++ A++ A++ A++
Heating A+ A+ A+ A+
Indoor Unit AUX-C-36CAC/I AUX-C-42CAC/I AUX-C-48CAC/I AUX-C-60CAC/I
Power Supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Decorative Panel AUX-P-01 AUX-P-01 AUX-P-02 AUX-P-02
Fan Motor Power [W] 100 100 100 100
Fan Speed (high / medium / low) [rpm] 750/700/650 750/700/650 750/700/650 750/700/650
Airflow (high / medium / low) [m3/h] 2000/1700/1600 2000/1700/1600 2000/1700/1600 2000/1700/1600
Sound Pressure Level (high / medium / low) [dB(A)] 52/50/48 52/50/48 51/49/47 53/49/47
Sound Power Level [dB(A)] 62 62 62 52
Indoor Unit Dimensions [mm] 840 x 840 x 288 840 x 840 x 288 840 x 840 x 288 840 x 840 x 288
Indoor Unit Weight (net) [kg] 29,0 29,0 29,5 29,5
Panel Dimensions [mm] 950 x 950 x 55 950 x 950 x 55 950 x 950 x 55 950 x 950 x 55
Panel Weight (net) [kg] 5,3 5,3 5,3 5,3
Outdoor Unit AUX-C-36CAO AUX-C-42CAO AUX-C-48CAO AUX-C-60CAO
Power Supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 380-415, 50, 3 380-415, 50, 3
Compressor Type rotary rotary rotary rotary
Airflow [m3/h] 4000 4000 7200 7200
Sound Pressure Level [dB(A)] 59 60 60 60
Sound Power Level [dB(A)] 69 70 70 70
Outdoor Unit Dimensions [mm] 970 x 395 x 805 970 x 395 x 805 940 x 370 x 1325 940 x 370 x 1325
Outdoor Unit Weight (net) [kg] 61,0 6,0 81,0 85,0
Refrigerant Type R32 R32 R32 R32
Factory Charge [kg] 2.75 2.75 2.70 3.05
Pipe Connections (diameter) Liquid [mm (inch)] 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8)
Gas [mm (inch)] 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8)
Condensate [mm (inch)] DN20 (R3/4) DN20 (R3/4) DN20 (R3/4) DN20 (R3/4)
Maximum Pipe Length [m] 65 65 65 65
Maximum Height Difference [m] 30 30 30 30
Outdoor Unit Operation (ambient temperature) Cooling [°C] -15~52 -15~52 -15~52 -15~52
Heating [°C] -22~24 -22~24 -22~24 -22~24
Operating Temperature Range [°C] 16~32 16~32 16~32 16~32
 We reserve the right for errors in descriptions, appearance, function, technical parameters, and dimensional drawings resulting from the continuous improvement of our devices.

FEATURES AND FUNCTIONS

Washable
air filter
R32
refrigerant
Wireless
controller
24-hour
timer
Cooling
mode
Fast cooling / heating
Heating
mode
AUTO
mode
Fan
mode
Dehumidifying mode
Vertical louver movement
Anti-Cold-Air function
Night
mode
I FEEL
function
TURBO
mode
Inverter
technology
Intelligent
defrosting function
Hydrophilic aluminum blades
Automatic
restart
Super
EMC
Cooling in low temperatures
We value your privacy

The website uses cookies to provide its services in accordance with the Cookies Policy. You can specify the conditions for storing or accessing cookies in your browser.