AUX Air Conditioners Poland ARV Systems
AUX Air Conditioners Poland ARV Systems

ARV6 air conditioning system

ARV6 is the latest generation of AUX system. High-tech devices are an ideal solution for commercial, office, hotel and residential buildings (ARV6 Mini). A wide range of indoor units and outdoor modules, which can be used to construct systems up to 246 kW, allows you to choose the right solution for a facility and the implementation of any, even the most unusual and demanding, systems.

  • Rewolucyjna technologia VER

    The evaporation and condensation temperature of the refrigerant significantly affects the cooling and heating performance as well as the energy efficiency of the air conditioning system.

    Utilizing the revolutionary VER energy efficiency technology, the ARV6 series outdoor units have a variety of different refrigerant temperature operating modes - Basic (default), Turbo and Economy modes. This enables flexible adjustment of the system's performance and its energy efficiency to the current cooling or heating demand, and thus control over the operating costs of the air-conditioning system.

    Thanks to the ability to select the operating mode, the air conditioning system can select the appropriate operating parameters to meet the current requirements of users, while maintaining optimal energy efficiency.

    AUX Air Conditioners Poland ARV Systems
  • High EER and COPR coeffcient

    By using only high-efficiency DC inverter compressors with improved vapor injection technology, all ARV6 series units achieve the highest energy efficiency coefficients in cooling and heating.

    AUX Air Conditioners Poland ARV Systems
  • 180˚ sine wave technology

    DC inverter compressor uses 180˚ sine wave control technology, which provides smooth running of the motor and a significant increase in efficiency comparing to traditional technology. Additionally, it reduces the noise level emitted by outdoor units.

    AUX Air Conditioners Poland ARV Systems
  • Brushless fan motor

    Brushless DC motor adjusts fan speed according to system pressure and working load to increase efficiency by 45%. Super Aero fan increases the air volume and higher static pressure.

    AUX Air Conditioners Poland ARV Systems
  • High Efficiency Motors

    High Efficiency Magnetic Motors improving the efficiency of traditional DC inverter compressors.

    AUX Air Conditioners Poland ARV Systems
  • High-efficiency heat exchanger

    The optimized 2 to 1 refrigerant circuit design increases the heat transfer efficiency and the liquid volume that flows to the evaporator.

    AUX Air Conditioners Poland ARV Systems
  • High-efficiency heat exchanger

    AUX Air Conditioners Poland ARV Systems
  • High efficiency DC inverter compressor with improved vapor injection technology

    AUX Air Conditioners Poland ARV Systems
AUX Air Conditioners Poland ARV Systems
AUX Air Conditioners Poland ARV Systems

The ARV6 series has been awarded
the prestigious Eurovent certificate,
which guarantees compliance with the declared parameters.

Features and functions

Health

AUX Air Conditioners Poland ARV Systems

Durable air filter
The indoor unit air filter is easy to remove and clean. The filter is resistant to multiple cleaning, which significantly extends its lifespan.

AUX Air Conditioners Poland ARV Systems

Self-cleaning function
Thanks to the comprehensive self-cleaning function, the interior of the air conditioner is kept clean by eliminating moisture and inhibiting the growth of bacteria, mold and unpleasant odors on the heat exchanger. It provides a clean and safe surrounding for users.

Comfort

AUX Air Conditioners Poland ARV Systems

& ldquo; Anti-Cold-Air & rdquo;
When starting the unit in heating mode, the indoor fan runs at the lowest speed to avoid blowing cold air. The airflow speed is automatically increased as the evaporator temperature rises up to the set value.

AUX Air Conditioners Poland ARV Systems

& ldquo; Follow me & rdquo; Function
The temperature sensor built into the wireless controller allows you to measure the temperature in the air-conditioned interior at a given moment. The measurement result is sent to the indoor unit, and the air conditioner automatically adjusts its operating parameters to the conditions in the room.

AUX Air Conditioners Poland ARV Systems

Fast cooling / heating
Thanks to the use of inverter technology, the air conditioning system can achieve full capacity shortly after starting operation and provide the desired temperature in the room quickly.

AUX Air Conditioners Poland ARV Systems

Independent drying
Thanks to the independent drying function, the air conditioner is able to lower the humidity level in the room to the desired value, increasing comfort for users.

AUX Air Conditioners Poland ARV Systems

Automatic louver movement & ldquo; Auto-Swing & rdquo;
The air louvers of the indoor unit automatically move horizontally - right and left (horizontal swing) or vertically - up and down (vertical swing), providing even distribution of the air in the room.

AUX Air Conditioners Poland ARV Systems

3D airflow function
Vertical and horizontal automatic movement of the louvers provides quick air distribution in all directions.

AUX Air Conditioners Poland ARV Systems

Turning on the display
After pressing the button & ldquo; Dimmer & rdquo; on the controller, the front panel display of the indoor unit is turned off.

AUX Air Conditioners Poland ARV Systems

Silent mode
In silent mode, the indoor unit of the air conditioner operates at a reduced sound pressure level, providing a comfortable surrounding in the room without excessive noise.

Energy-saving

AUX Air Conditioners Poland ARV Systems

180 & sine wave control technology
The DC inverter compressor uses 180˚ sine wave control technology, which provides smooth running of the motor and a significant increase in efficiency comparing to traditional technology. Additionally, it reduces the noise level of outdoor units.

AUX Air Conditioners Poland ARV Systems

DC inverter technology
DC control, DC compressor, DC indoor and outdoor unit fan. The use of inverter technology provides a significant reduction in energy consumption compared to standard devices.

AUX Air Conditioners Poland ARV Systems

Night mode
After switching on the sleep function, the device increases the set temperature by 1 ° C per hour during the first two hours of operation in cooling mode (in heating mode it lowers the temperature at the same rate ). For the next 5 hours, it keeps the temperature constant, after which the air conditioner turns off. It provides the highest comfort during night's rest and reduces the electricity consumption of the device.

AUX Air Conditioners Poland ARV Systems

Hydrophilic coated fins
Hydrophilic coated fins increase efficiency by 10% and improve the speed of condensation.

Reliability

AUX Air Conditioners Poland ARV Systems

Self-diagnosis function
The device monitors for malfunctions and shuts down in case of failure. An error code appears on the display of the indoor unit (or on the wired controller) indicating the type of failure, which greatly facilitates service.

AUX Air Conditioners Poland ARV Systems

Low temperature cooling
Top-class components, such as a highly efficient compressor and a high quality heat exchanger, provides reliable operation of the air conditioner in cooling mode even at very low ambient temperatures.

AUX Air Conditioners Poland ARV Systems

Smart defrosting
Smart defrosting system provides almost uninterrupted operation of the air conditioner in heating mode. Defrosting mode is activated only when necessary and only for the time required to defrost the heat exchanger, which allows the unit to operate more efficiently while heating the room.

AUX Air Conditioners Poland ARV Systems

Compressor crankcase heater
An additional strip heater increases the compressor oil temperature in winter and prevents water freezing, increasing heat transfer efficiency.

AUX Air Conditioners Poland ARV Systems

Frost-resistant design
The unique design of the exchanger increases the temperature on the casing, which prevents the accumulation of water coming from the defrosting process, increasing the heat exchange efficiency and eliminating the problem of water drainage.

AUX Air Conditioners Poland ARV Systems

Gold coated fins of the heat exchanger
The unique gold coating on the surface of the heat exchanger effectively prevents the growth of bacteria and improves the unit's operating efficiency. It also effectively protects the heat exchanger surface against corrosion, extending the lifespan of the device.

AUX Air Conditioners Poland ARV Systems

Fireproof electrical box
The device is equipped with a high fireproof electrical box, which prevents the possibility of fire in the event of a short circuit inside the box.

Convenience

AUX Air Conditioners Poland ARV Systems

24H timer
The timer function allows the user to set the exact time to automatically turn the air conditioner on and off.

AUX Air Conditioners Poland ARV Systems

Built-in drain pump
The device is equipped with a condensate pump with a large lifting height.

AUX Air Conditioners Poland ARV Systems

Double-sided condensate drainage
Possibility to connect the condensate drainage system both on the left and on the right side of the indoor unit, which greatly facilitates the installation.

AUX Air Conditioners Poland ARV Systems

Digital display
The digital display panel shows the current operating mode of the device. Parameters such as room temperature and operating mode are displayed clearly while operating.

AUX Air Conditioners Poland ARV Systems

Washable air filter
The air filter of the indoor unit can be easily removed and cleaned under running water, which allows you to maintain the high efficiency of the unit and the quality of air.

AUX Air Conditioners Poland ARV Systems

Automatic restart
In the event of a power failure, the device records the last settings and restarts after resuming the power supply, automatically restoring the previously set operating mode.

Control

AUX Air Conditioners Poland ARV Systems

Wireless controller
The wireless remote controller allows you to remotely control the air conditioner - turn the device on and off and select settings and functions, including operating mode, airflow temperature, fan speed or airflow direction.

AUX Air Conditioners Poland ARV Systems

Wired controller
The wired controller is installed on the wall in the room where the air conditioner is located. It allows you to easily and conveniently control the operation of the unit.

AUX Air Conditioners Poland ARV Systems

Central controller
The central controller allows you to control the operation of many air conditioning systems. It allows you to control the operation of several indoor units.

AUX Air Conditioners Poland ARV Systems

Wi-Fi control module
The WiFi module allows you to control the operation of the air conditioner using a smartphone, tablet or computer connected to the Internet, anywhere in the world.

Technical data

ARV6 Modular

AUX Air Conditioners Poland ARV Systems

COMBINATION TABLE OF OUTDOOR UNITS

Total cooling capacity of the system   Outdoor units ARV 6   
[kW][HP]8HP10HP12HP14HP 16HP18HP20HP22HP
25.28       
28.010       
33.512       
40.014       
45.016       
50.418       
56.020       
61.522       
67.024         
73.026       
78.528       
84.030       
89.532       
95.034       
101.536       
106.538       
111.940       
117.542       
123.044         
128.546         
134.548       
140.050       
145.552       
151.054         
156.556         
163.058         
168.060         
173.462         
179.064         
184.566          
190.068           
196.070         
201.572         
207.074         
212.576          
218.078          
224.580          
229.582          
234.984          
240.586          
246.086           
Model ARV-H250/SR1MVARV-H280/SR1MVARV-H330/SR1MVARV-H400/SR1MV
HP 8101214
Cooling capacity[kW]25,228,033,540,0
Heating capacity[kW]25,228,033,540,0
Power[V~, Hz, Ph]380~415,3,50/60380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60
Power consumption in cooling mode[kW]5,316,118,489,90
Power consumption in heating mode[kW]4,65,236,388,25
EER / COP[W/W]4,75 / 5,484,58 / 5,353,95 / 5,254,04 / 4,85
SEER/SCOP[W/W]6,7 / 4,26,5 / 4,07,2 / 4,26,5 / 4,3
Airflow[m3/h]12000120001200014000
Acoustic pressure level[dB(A)]≤58≤58≤58≤61
CompressorCompressor type DC inverterDC inverterDC inverterDC inverter
Number of compressors 1111
Fan motorCompressor type DC motorDC motorDC motorDC motor
Number of compressors 1112
Max. Number of indoor units 13162023
IDU / ODU Capacity ratio range[%]50 - 15050 - 15050 - 15050 - 150
Dimensions (W x D x H)[mm]990x765x1635990x765x1635990x765x16351340x765x1635
Net wegight[kg]215215230265
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm]12,712,712,715,88
Gas[mm]22,222,222,228,6
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24
 
Model ARV-H450/SR1MVARV-H500/SR1MVARV-H560/SR1MVARV-H610/SR1MV
HP 16182022
Cooling capacity[kW]45,050,456,061,5
Heating capacity[kW]45,050,456,061,5
Power[V~, Hz, Ph]380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60
Power consumption in cooling mode[kW]11,8212,6315,3418,90
Power consumption in heating mode[kW]9,7811,6913,8315,44
EER / COP[W/W]3,81 / 4,603,99 / 4,313,65 / 4,053,25 / 3,98
SEER/SCOP[W/W]6,3 / 4,26,0 / 4,05,6 / 3,65,2 / 3,5
Airflow[m3/h]14000160001600016000
Acoustic pressure level[dB(A)]≤61≤63≤63≤63
CompressorCompressor type DC inverterDC inverterDC inverterDC inverter
Number of compressors 1222
Fan motorCompressor type DC motorDC motorDC motorDC motor
Number of compressors 2222
Max. Number of indoor units 26303336
IDU / ODU Capacity ratio range[%]50 - 15050 - 15050 - 15050 - 150
Dimensions (W x D x H)[mm]1340x765x16351340x765x16351340x765x16351340x765x1635
Net wegight[kg]265330330330
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm]15,8815,8815,8815,88
Gas[mm]28,628,628,628,6
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24
Model ARV-H670/SR1MVARV-H730/SR1MVARV-H780/SR1MVARV-H840/SR1MV
HP 24262830
Combination[HP]12 + 1210 + 1612 + 1610 + 20
Cooling capacity[kW]67,073,078.584,0
Heating capacity[kW]67,073,078.584,0
Power[V~, Hz, Ph]380~415,3,50/60380~415,3,50/60380~415,3,50/60380~415,3,50/60
Power consumption in cooling mode[kW]16,9617,9320,3021,45
Power consumption in heating mode[kW]12,7615,0116,1619,06
EER / COP[W/W]3,95 / 5,254,07 / 4,863,87 / 4,863,92 / 4,41
SEER/SCOP[W/W]7,2 / 4,26,5 / 4,27,2 / 4,27,2 / 4,2
Airflow[m3/h]12000x212000 + 1400012000+ 1400012000 + 16000
Acoustic pressure level[dB(A)]≤58≤61≤61≤63
CompressorCompressor type DC inverterDC inverterDC inverterDC inverter
Number of compressors 2223
Fan motorCompressor type DC motorDC motorDC motorDC motor
Number of compressors 2333
Max. Number of indoor units 40424649
IDU / ODU Capacity ratio range[%]50 - 20050 - 20050 - 20050 - 200
Dimensions (W x D x H)[mm](990x765x1635)x2990x765x1635 + 1340x765x1635990x765x1635 + 1340x765x1635990x765x1635+ 1340x765x1635
Net wegight[kg]230x2215 + 265230+265215 + 330
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm]19,05 (3/4)19,05 (3/4)19,05 (3/4)19,05 (3/4)
Gas[mm]34,93 (11/8)34,93 (11/8)34,93 (11/8)34,93 (11/8)
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24
Model ARV-H890/SR1MVARV-H950/SR1MVARV-H1010/SR1MVARV-H1060/SR1MV
HP 32343638
Combination[HP]10 + 2212 + 2214 + 2216 + 22
Cooling capacity[kW]89,595,0101,5106,5
Heating capacity[kW]89,595,0101,5106,5
Power[V~, Hz, Ph]380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60
Power consumption in cooling mode[kW]25,0127,3828,8030,72
Power consumption in heating mode[kW]20,6721,8223,6925,22
EER / COP[W/W]3,58 / 4,333,47 / 4,353,52 / 4,283,47 / 4,22
SEER/SCOP[W/W]6,5 / 4,07,2 / 4,26,5 / 4,36,3 / 4,2
Airflow[m3/h]12000 + 1600012000 + 1600014000 + 1600014000 + 16000
Acoustic pressure level[dB(A)]≤63≤63≤63≤63
CompressorCompressor type DC inverterDC inverterDC inverterDC inverter
Number of compressors 3333
Fan motorCompressor type DC motorDC motorDC motorDC motor
Number of compressors 3344
Max. Number of indoor units 52565962
IDU / ODU Capacity ratio range[%]50 - 20050 - 20050 - 20050 - 200
Dimensions (W x D x H)[mm]990x765x1635 + 1340x765x1635990x765x1635 + 1340x765x1635(1340x765x1635)x2(1340x765x1635)x2
Net wegight[kg]215 + 330230 + 330265+330265+330
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm]19,05 (3/4)19,05 (3/4)19,05 (3/4)19,05 (3/4)
Gas[mm]34,93 (11/8)34,93 (11/8)38,1 (3/2)38,1 (3/2)
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24
Model ARV-H1120/SR1MVARV-H1170/SR1MVARV-H1230/SR1MVARV-H1280/SR1MV
HP 40424446
Combination[HP]18 + 2220 + 2222 + 2212 + 12 + 22
Cooling capacity[kW]111,9117,5123,0128,5
Heating capacity[kW]111,9117,5123,0128,5
Power[V~, Hz, Ph]380~415,3,50/60380~415,3,50/60380~415,3,50/60380~415,3,50/60
Power consumption in cooling mode[kW]31,5334,2437,8035,86
Power consumption in heating mode[kW]27,1329,2730,8828,20
EER / COP[W/W]3,55 / 4,123,43 / 4,013,25 / 3,983,58 / 4,56
SEER/SCOP[W/W]6,0 / 4,05,6 / 3,65,2 / 3,57,2 / 4,2
Airflow[m3/h]16000x216000x216000x212000x2 + 16000
Acoustic pressure level[dB(A)]≤63≤63≤63≤63
CompressorCompressor type DC inverterDC inverterDC inverterDC inverter
Number of compressors 4444
Fan motorCompressor type DC motorDC motorDC motorDC motor
Number of compressors 4444
Max. Number of indoor units 64646464
IDU / ODU Capacity ratio range[%]50 - 20050 - 20050 - 20050 - 200
Dimensions (W x D x H)[mm](1340x765x1635)x2(1340x765x1635)x2(1340x765x1635)x2(990x765x1635)x2 + 1340x765x1635
Net wegight[kg]330x2330x2330x2230x2+330
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm]19,05 (3/4)19,05 (3/4)19,05 (3/4)19,05 (3/4)
Gas[mm]38,1 (3/2)38,1 (3/2)38,1 (3/2)38,1 (3/2)
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24
Model ARV-H1340/SR1MVARV-H1400/SR1MVARV-H1450/SR1MVARV-H1510/SR1MV
HP 48505254
Combination[HP]10 + 16 + 2212 + 16 + 2210 + 20 + 2210 + 22 + 22
Cooling capacity[kW]134,5140,0145,5151,0
Heating capacity[kW]134,5140,0145,5151,0
Power[V~, Hz, Ph]380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60
Power consumption in cooling mode[kW]36,8339,2040,3543,91
Power consumption in heating mode[kW]30,4531,6034,5036,11
EER / COP[W/W]3,65 / 4,423,57 / 4,433,61 / 4,223,44 / 4,18
SEER/SCOP[W/W]6,5 / 4,27,2 / 4,26,5 / 4,06,5 / 4,0
Airflow[m3/h]12000 +14000 +1600012000 + 14000 + 1600012000+16000x212000 +16000x2
Acoustic pressure level[dB(A)]≤63≤63≤63≤63
CompressorCompressor type DC inverterDC inverterDC inverterDC inverter
Number of compressors 4455
Fan motorCompressor type DC motorDC motorDC motorDC motor
Number of compressors 5555
Max. Number of indoor units 64646464
IDU / ODU Capacity ratio range[%]50 - 20050 - 20050 - 20050 - 200
Dimensions (W x D x H)[mm]990x765x1635 + (1340x765x1635)x2990x765x1635 + (1340x765x1635)x2990x765x1635+ (1340x765x1635)x2990x765x1635 + (1340x765x1635)x2
Net wegight[kg]215 + 265 + 330230 + 265 + 330215 + 330x2215 + 330x2
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm]19,05 (3/4)19,05 (3/4)19,05 (3/4)19,05 (3/4)
Gas[mm]38,1 (3/2)41,3 (13/8)41,3 (13/8)41,3 (13/8)
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24
Model ARV-H1560/SR1MVARV-H1630/SR1MVARV-H1680/SR1MVARV-H1730/SR1MV
HP 56586062
Combination[HP]12 + 22 + 2214 + 22 + 2216 + 22 + 2218 + 22 +22
Cooling capacity[kW]156,5163,0168,0173,4
Heating capacity[kW]156,5163,0168,0173,4
Power[V~, Hz, Ph]380~415,3,50/60380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60
Power consumption in cooling mode[kW]46,2847,7049,6250,43
Power consumption in heating mode[kW]37,2639,1340,6642,57
EER / COP[W/W]3,38 / 4,203,42 / 4,173,39 / 4,133,44 / 4,07
SEER/SCOP[W/W]7,2 / 4,26,5 / 4,36,3 / 4,26,0 / 4,0
Airflow[m3/h]12000 + 16000x214000 + 16000x214000+ 16000x216000x3
Acoustic pressure level[dB(A)]≤63≤63≤63≤63
CompressorCompressor type DC inverterDC inverterDC inverterDC inverter
Number of compressors 5556
Fan motorCompressor type DC motorDC motorDC motorDC motor
Number of compressors 5666
Max. Number of indoor units 64646464
IDU / ODU Capacity ratio range[%]50 - 20050 - 20050 - 20050 - 200
Dimensions (W x D x H)[mm]90x765x1635 + (1340x765x1635)x2(1340x765x1635)x3(1340x765x1635)x3(1340x765x1635)x3
Net wegight[kg]230+330x2265 + 330x2265+330x2330x3
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm]19,05 (3/4)19,05 (3/4)19,05 (3/4)19,05 (3/4)
Gas[mm]41,3 (13/8)41,3 (13/8)41,3 (13/8)41,3 (13/8)
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24
Model ARV-H1790/SR1MVARV-H1840/SR1MVARV-H1900/SR1MVARV-H1960/SR1MV
HP 64666870
Combination[HP]20 + 22 + 2222 + 22 + 2212 + 12 + 22 + 2210 + 16 + 22 + 22
Cooling capacity[kW]179,0184,5190,0196,0
Heating capacity[kW]179,0184,5190,0196,0
Power[V~, Hz, Ph]380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60
Power consumption in cooling mode[kW]53,1456,7054,7655,73
Power consumption in heating mode[kW]44,7146,3243,6445,89
EER / COP[W/W]3,37 / 4,003,25 / 3,983,47 / 4,353,52 / 4,27
SEER/SCOP[W/W]5,6 / 3,65,2 / 3,57,2 / 4,26,5 / 4,2
Airflow[m3/h]16000x316000x312000x2 + 16000x212000 + 14000 + 16000x2
Acoustic pressure level[dB(A)]≤63≤63≤63≤63
CompressorCompressor type DC inverterDC inverterDC inverterDC inverter
Number of compressors 6666
Fan motorCompressor type DC motorDC motorDC motorDC motor
Number of compressors 6667
Max. Number of indoor units 64646464
IDU / ODU Capacity ratio range[%]50 - 20050 - 20050 - 20050 - 200
Dimensions (W x D x H)[mm](1340x765x1635)x3(1340x765x1635)x3(990x765x1635)x2 + (1340x765x1635)x2990x765x1635+ (1340x765x1635)x3
Net wegight[kg]330x3330x3230x2+330x2215 + 265 + 330x2
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm]19,05 (3/4)19,05 (3/4)22,2 (7/8)22,2 (7/8)
Gas[mm]41,3 (13/8)41,3 (13/8)44,5 (7/4)44,5 (7/4)
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24
Model ARV-H2010/SR1MVARV-H2070/SR1MVARV-H2120/SR1MVARV-H2180/SR1MV
HP 72747678
Combination[HP]12 + 16 + 22 + 2210 + 20 + 22 + 2210 + 22 + 22 + 2212 + 22 + 22 + 22
Cooling capacity[kW]201,5207,0212,5218,0
Heating capacity[kW]201,5207,0212,5218,0
Power[V~, Hz, Ph]380~415,3,50/60380~415,3,50/60380~415,3,50/60380~415,3,50/60
Power consumption in cooling mode[kW]58,1059,2562,8165,18
Power consumption in heating mode[kW]47,0449,9451,5552,70
EER / COP[W/W]3,47 / 4,283,49 / 4,143,38 / 4,123,34 / 4,14
SEER/SCOP[W/W]7,2 / 4,26,5 / 4,06,5 / 4,07,2 / 4,2
Airflow[m3/h]12000 +14000 +16000x212000 + 16000x312000 + 16000x312000 + 16000x3
Acoustic pressure level[dB(A)]≤63≤63≤63≤63
CompressorCompressor type DC inverterDC inverterDC inverterDC inverter
Number of compressors 6777
Fan motorCompressor type DC motorDC motorDC motorDC motor
Number of compressors 7777
Max. Number of indoor units 64646464
IDU / ODU Capacity ratio range[%]50 - 20050 - 20050 - 20050 - 200
Dimensions (W x D x H)[mm]990x765x1635 + (1340x765x1635)x3990x765x1635 + (1340x765x1635)x3990x765x1635 + (1340x765x1635)x3990x765x1635 + 1340x765x1635)x3
Net wegight[kg]230+265+330x2215 + 330x3215 + 330x3230 + 330x3
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm]22,2 (7/8)22,2 (7/8)22,2 (7/8)22,2 (7/8)
Gas[mm]44,5 (7/4)44,5 (7/4)44,5 (7/4)44,5 (7/4)
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24
Model ARV-H2240/SR1MVARV-H2290/SR1MVARV-H2350/SR1MVARV-H2400/SR1MVARV-H2460/SR1MV
HP 8082848688
Combination[HP]14 + 22 + 22 + 2216 + 22 + 22 + 2218 + 22 + 22 + 2220 + 22 + 22 + 2222 + 22 + 22 + 22
Cooling capacity[kW]224,5229,5234,9240,5246,0
Heating capacity[kW]224,5229,5234,9240,5246,0
Power[V~, Hz, Ph]380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60380~415, 3, 50/60
Power consumption in cooling mode[kW]66.6068.5269.3372.0475.60
Power consumption in heating mode[kW]54.5756.1058.0160.1561.76
EER / COP[W/W]3.37 / 4.113.35 / 4.093.39 / 4.053.34 / 4.003.25 / 3.98
SEER/SCOP[W/W]6,5 / 4,36,3 / 4,26,0 / 4,05,6 / 3,65,2 / 3,5
Airflow[m3/h]14000 + 16000x314000+16000x316000x416000x416000x4
Acoustic pressure level[dB(A)]≤63≤63≤63≤63≤63
CompressorCompressor type DC inverterDC inverterDC inverterDC inverterDC inverter
Number of compressors 77888
Fan motorCompressor type DC motorDC motorDC motorDC motorDC motor
Number of compressors 88888
Max. Number of indoor units 6464646464
IDU / ODU Capacity ratio range[%]50 - 20050 - 20050 - 20050 - 20050 - 200
Dimensions (W x D x H)[mm](1340x765x1635)x4(1340x765x1635)x4(1340x765x1635)x4(1340x765x1635)x4(1340x765x1635)x4
Net wegight[kg]265+330x3265 + 330x3330x4330x4330x4
Refrigerant type R410AR410AR410AR410AR410A
Piping dimensionsLiquid[mm]22,2 (7/8)22,2 (7/8)22,2 (7/8)22,2 (7/8)22,2 (7/8)
Gas[mm]44,5 (7/4)44,5 (7/4)44,5 (7/4)44,5 (7/4)44,5 (7/4)
Operating rangeCooling[°C]-15~55-15~55-15~55-15~55-15~55
Heating[°C]-30~24-30~24-30~24-30~24-30~24

Capacities are based on the following conditions:
Cooling capacity: indoor temperature 27 ° C (DB dry thermometer) / 19 ° C (wet thermometer WB); outdoor temperature 35 ° C (DB dry thermometer) / 24 ° C (WB wet thermometer).
Heating capacity: indoor temperature 20 ° C (DB dry thermometer); outdoor temperature 7 ° C (DB dry thermometer) / 6 ° C (WB wet thermometer).
Refrigeration piping length: Equivalent installation length: 7.5m; 0 m level difference.
Sound level values measured in an anechoic chamber at 1 meter from the unit and 1.3 meters above the floor.
These functions and specifications are for information purposes only and are subject to change without notice.
The devices contain fluorinated greenhouse gases R410A.

Technical data

ARV6 Mini

one phase, 50/60Hz

Model ARV-H080/NR1ARV-H100/NR1ARV-H120/NR1ARV-H140/NR1ARV-H160/NR1
Cooling capacity[kW]8,0010,0012,3014,0016,00
Heating capacity[kW]9,0011,5013,2016,0018,00
Power[V~, Hz, Ph]220-240,50/60,1220-240,50/60,1220-240,50/60,1220-240,50/60,1220-240,50/60,1
Power consumptionCooling[kW]2,303,003,253,954,80
Heating[kW]2,403,203,414,054,80
Operating currentCooling[A]10,1013,2014,3017,3021,10
Heating[A]10,5014,0015,0017,8021,10
EER / COP[W/W]3,48 / 3,753,33 / 3,593,78 / 3,873,54 / 3,953,33 / 3,75
SEER/SCOP[W/W]6,20 / 4,206,10 / 4,106,10 / 4,106,10 / 4,006,10 / 4,00
Airflow[m3/h]41544154720072007200
Acoustic pressure level[dB(A)]5656575757
Max. level difference between indoor and outdoor unit[m]5050505050
Max. level difference between indoor units[m]1010151515
Max. distance from the first pipe tee to the farthest indoor unit[m]4040404040
Total piping length[m]100100150150150
Max. Number of indoor units 45789
IDU / ODU Capacity ratio range[%]50~13050~13050~13050~13050~130
Dimensions (W x D x H)[mm]970x370x803970x370x803970x340x1320970x340x1320970x340x1320
Net wegight[kg]6666868693
Refrigerant type R410AR410AR410AR410AR410A
Piping dimensionsLiquid[mm (inches)]9,52 (3/8)9,52 (3/8)9,52 (3/8)9,52 (3/8)9,52 (3/8)
Gas[mm (inches)]15,88 (5/8)15,88 (5/8)15,88 (5/8)15,88 (5/8)19,05 (3/4)
Operating rangeCooling[°C]-15~49-15~49-15~49-15~49-15~49
Heating[°C]-15~27-15~27-15~27-15~27-15~27

Three-phase, 50 / 60Hz

Model ARV-H140/SR1ARV-H160/SR1ARV-H220/SR1DCS1ARV-H260/SR1DCS1
Cooling capacity[kW]14,0016,0022,4026,00
Heating capacity[kW]16,0018,0024,5028,50
Power[V~, Hz, Ph]380~415,50/60,3380~415,50/60,3380~415,50/60,3380~415,50/60,3
Power consumptionCooling[kW]4,114,706,807,60
Heating[kW]4,104,615,906,80
Operating currentCooling[A]6,156,9611,1012,40
Heating[A]6,106,769,6011,10
EER / COP[W/W]3,41 / 3,903,40 / 3,903,29 / 4,153,42 / 4,19
SEER/SCOP[W/W]6,10 / 4,006,10 / 4,006,10 / 4,006,10 / 4,00
Airflow[m3/h]720072001050010500
Acoustic pressure level[dB(A)]57576060
Max. level difference between indoor and outdoor unit[m]50505050
Max. level difference between indoor units[m]881010
Max. distance from the first pipe tee to the farthest indoor unit[m]40404040
Total piping length[m]150150250250
Max. Number of indoor units 891315
IDU / ODU Capacity ratio range[%]50~13050~13050~13050~130
Dimensions (W x D x H)[mm]940x370x1325940x370x13251120x400x15101120x400x1510
Net wegight[kg]103103165165
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm (inches)]9,52 (3/8)9,52 (3/8)9,52 (3/8)9,52 (3/8)
Gas[mm (inches)]19,05 (3/4)19,05 (3/4)22,2 (7/8)22,2 (7/8)
Operating rangeCooling[°C]-15~49-15~49-15~49-15~49
Heating[°C]-15~27-15~27-15~27-15~27

Capacities are based on the following conditions:
Cooling capacity: indoor temperature 27 ° C (DB dry thermometer) / 19 ° C (wet thermometer WB); outdoor temperature 35 ° C (DB dry thermometer) / 24 ° C (WB wet thermometer).
Heating capacity: indoor temperature 20 ° C (DB dry thermometer); outdoor temperature 7 ° C (DB dry thermometer) / 6 ° C (WB wet thermometer).
Refrigeration piping length: Equivalent installation length: 7.5m; 0 m level difference.
Sound level values measured in an anechoic chamber at 1 meter from the unit and 1.3 meters above the floor.
These functions and specifications are for information purposes only and are subject to change without notice.
The devices contain fluorinated greenhouse gases R410A.

AUX Air Conditioners Poland ARV Systems

Technical data

Indoor units

Wall units Wall units
4-way cassette units AUX ARV 4-way cassette units
2-way cassette units AUX ARV 2-way cassette units
1-way cassette units AUX ARV 1-way cassette units
Slim duck units AUX ARV Slim duck units
Medium ESP duct units AUX ARV Medium ESP duct units
High ESP duct units AUX ARV High ESP duct units
Floor/ceiling units AUX ARV Floor/ceiling units

Wall units

Model ARVWM-H022/R1X(L)ARVWM-H028/R1X(L)ARVWM-H036/R1X(L)
Cooling capacity[kW]2.22.83.6
Heating capacity[kW]2.534.3
Powerz, H220~240,50/60,1220~240,50/60,1220~240,50/60,1
Nominal power[W]141414
Airflow (high/medium/low)[m3/h]650/600/580650/600/580650/600/580
Acoustic pressure level (high/medium/low)[dB(A)]38/33/2738/33/2738/33/27
Dimensions (W x D x H)[mm]850x300x198850x300x198850x300x198
Net wegight[kg]101010
Refrigerant type-R410AR410AR410A
Piping dimensionsLiquid[mm(cale)]6.35 (1/4)6.35 (1/4)6.35 (1/4)
Gas[mm(cale)]9.52 (3/8)9.52 (3/8)9.52 (3/8)
Condensate[mm]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)

Model ARVWM-H045/R1X(L)ARVWM-H056/R1X(L)ARVWM-H071/R1X(L)
Cooling capacity[kW]4.55.67.1
Heating capacity[kW]568
Power[V-, Hz, Ph]220-240,50/60,1220-240,50/60,1220-240,50/60,1
Nominal power[W]252535
Airflow (high/medium/low)[m3/h]850/750/650850/750/6501200/950/800
Acoustic pressure level (high/medium/low)[dB(A)]45/41/3545/41/3548/45/39
Dimensions (W x D x H)[mm]970x315x235970x315x2351100x330x235
Net wegight[kg]141416
Refrigerant type R410AR410AR410A
Piping dimensionsLiquid[mm (inches)]6.35 (1/4)6.35 (1/4)6.35 (1/4)
Gas[mm (inches)]12.7 (1/2)12.7 (1/2)15.88 (5/8)
Condensate[mm]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)
 

4-way cassette units

Model ARVCA-H028/R1XARVCA-H036/R1XARVCA-H045/R1XARVCA-H056/R1X
Panel model MB09MB09MB09MB09
Cooling capacity[kW]2,83,64,55,6
Heating capacity[kW]3,04,35,06,0
Power[V~, Hz, Ph]220~240,50/60,1220~240,50/60,1220~240,50/60,1220~240,50/60,1
Nominal power[W]33,533,533,533,5
Airflow (high/medium/low)[m3/h]700/600/530700/600/530700/600/530700/600/530
Acoustic pressure level (high/medium/low)[dB(A)]45/41/3545/41/3545/41/3545/41/35
Unit dimensions (W x D x H)[mm]570x630x260570x630x260570x630x260570x630x260
Panel dimensions (W x D x H)[mm]650x650x55650x650x55650x650x55650x650x55
Net wegight[kg]19,019,019,019,0
Net panel weight[kg]2,22,22,22,2
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm (inches)]6,35 (1/4)6,35 (1/4)6,35 (1/4)6,35 (1/4)
Gas[mm (inches)]12,7 (1/2)12,7 (1/2)12,7 (1/2)12,7 (1/2)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)
Model ARVCA-H071/R1XARVCA-H080/R1XARVCA-H090/R1XARVCA-H100/R1X
Panel model MB08MB08MB08MB08
Cooling capacity[kW]7,18,09,010,0
Heating capacity[kW]8,010,011,012,0
Power[V~, Hz, Ph]220~240,50/60,1220~240,50/60,1220~240,50/60,1220~240,50/60,1
Nominal power[W]40406565
Airflow (high/medium/low)[m3/h]1250/1040/9101250/1040/9101500/1200/10501500/1200/1050
Acoustic pressure level (high/medium/low)[dB(A)]38/34/3038/34/3043/39/3843/39/38
Unit dimensions (W x D x H)[mm]835x835x250835x835x250835x835x250835x835x250
Panel dimensions (W x D x H)[mm]950x950x55950x950x55950x950x55950x950x55
Net wegight[kg]24,024,025,025,0
Net panel weight[kg]5,35,35,35,3
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm (inches)]9,52 (3/8)9,52 (3/8)9,52 (3/8)9,52 (3/8)
Gas[mm (inches)]15,88 (5/8)15,88 (5/8)15,88 (5/8)15,88 (5/8)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)

Model ARVCA-H112/R1XARVCA-H125/R1XARVCA-H140/R1X
Panel model MB08MB08MB08
Cooling capacity[kW]11,212,514,0
Heating capacity[kW]12,813,315,0
Power[V~, Hz, Ph]220~240,50/60,1220~240,50/60,1220~240,50/60,1
Nominal power[W]101101101
Airflow (high/medium/low)[m3/h]1800/1440/12601800/1440/12601800/1440/1260
Acoustic pressure level (high/medium/low)[dB(A)]45/42/4045/42/4046/43/41
Unit dimensions (W x D x H)[mm]835x835x290835x835x290835x835x290
Panel dimensions (W x D x H)[mm]950x950x55950x950x55950x950x55
Net wegight[kg]26,026,026,0
Net panel weight[kg]5,35,35,3
Refrigerant type R410AR410AR410A
Piping dimensionsLiquid[mm (inches)]9,52 (3/8)9,52 (3/8)9,52 (3/8)
Gas[mm (inches)]15,88 (5/8)15,88 (5/8)15,88 (5/8)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)

2-way cassette units

Model  ARVC2-H028/4R1AARVC2-H036/4R1AARVC2-H045/4R1AARVC2-H056/4R1AARVC2-H071/4R1A
Cooling capacity[kW]2.83.64.55.67.1
Heating capacity[kW]3.2456.38
Power[V~, Hz, Ph]220~240,50,1220~240,50,1220~240,50,1220~240,50,1220~240,50,1
Nominal power[W]6262858594
Airflow (high/medium/low)[m3/h]616/523/462616/523/462900/765/657900/765/6571165/990/873
Acoustic pressure level (high/medium/low)[dB(A)]39/36/3239/36/3245/41/3945/41/3947/43/40
Unit dimensions (W x D x H)[mm]960x520x315960x520x315960x520x315960x520x3151200x520x315
Panel dimensions (W x D x H)[mm]1203x630x331203x630x331203x630x331203x630x331443x630x33
Net wegight[kg]41/4441/4442/4542/4547.5/51
Net panel weight[kg]5/75/75/75/77.5/9.5
Refrigerant type R410aR410aR410aR410aR410a
Piping dimensionsLiquid[mm (inches)]6.35 (1/4)6.35 (1/4)6.35 (1/4)6.35 (1/4)9.52 (3/8)
Gas[mm (inches)]12.7 (1/2)12.7 (1/2)12.7 (1/2)12.7 (1/2)15.88 (5/8)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)
 

1-way cassette units

Model  ARVC1-H028/4R1AARVC1-H036/4R1AARVC1-H045/4R1AARVC1-H056/4R1AARVC1-H071/4R1A
Cooling capacity[kW]2.83.64.55.67.1
Heating capacity[kW]3.2456.38
Power[V~, Hz, Ph]220~240,50,1220~240,50,1220~240,50,1220~240,50,1220~240,50,1
Nominal power[W]4040455050
Airflow (high/medium/low)[m3/h]600/480/360600/480/360720/570/4501000/850/7501000/850/750
Acoustic pressure level (high/medium/low)[dB(A)]39/35/3139/35/3142/39/3547/43/4047/43/40
Unit dimensions (W x D x H)[mm]870x460x250870x460x250870x460x2501180x495x2901180x495x290
Panel dimensions (W x D x H)[mm]1070x520x331070x520x331070x520x331380x550x331380x550x33
Net wegight[kg]27/3027/3030/3439/4439/44
Net panel weight[kg]3/53/53/55/75/7
Refrigerant type R410aR410aR410aR410aR410a
Piping dimensionsLiquid[mm (inches)]6.35 (1/4)6.35 (1/4)6.35 (1/4)9.52 (3/8)9.52 (3/8)
Gas[mm (inches)]12.7 (1/2)12.7 (1/2)12.7 (1/2)15.88 (5/8)15.88 (5/8)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)
 

Slim duck units

Model  ARVSD-H022/R1XARVSD-H028/R1XARVSD-H036/R1X
Cooling capacity[kW]2,22,83,6
Heating capacity[kW]2,53,04,3
Power[V~, Hz, Ph]220~240, 50/60, 1220~240, 50/60, 1220~240, 50/60, 1
Nominal power[W]575761
Airflow (high/medium/low)[m3/h]480/390/320480/390/320560/430/390
Acoustic pressure level (high/medium/low)[dB(A)]30/26/2330/26/2332/28/25
ESP external static pressure[Pa]10/3010/3010/30
Dimensions (W x D x H)[mm]840x460x185840x460x185840x460x185
Net wegight[kg]15,515,516,5
Refrigerant type R410AR410AR410A
Piping dimensionsLiquid[mm (inches)]6,35 (1/4)6,35 (1/4)6,35 (1/4)
Gas[mm (inches)]9,52 (3/8)9,52 (3/8)12,7 (1/2)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)
 
Model ARVSD-H045/R1XARVSD-H056/R1XARVSD-H071/R1X
Cooling capacity[kW]4,55,67,1
Heating capacity[kW]5,06,08,0
Power[V~, Hz, Ph]220~240, 50/60, 1220~240, 50/60, 1220~240, 50/60, 1
Nominal power[W]808090
Airflow (high/medium/low)[m3/h]850/680/575850/680/5751000/810/685
Acoustic pressure level (high/medium/low)[dB(A)]38/35/3238/35/3239/36/32
ESP external static pressure[Pa]10/3010/3010/30
Dimensions (W x D x H)[mm]1160x460x1851160x460x1851160x460x185
Net wegight[kg]202022
Refrigerant type R410AR410AR410A
Piping dimensionsLiquid[mm (inches)]6,35 (1/4)6,35 (1/4)9,52 (3/8)
Gas[mm (inches)]12,7 (1/2)12,7 (1/2)15,88 (5/8)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20(R3/4)
 

Medium ESP duct units

Model ARVMD-H045/R1XARVMD-H056/R1XARVMD-H071/R1XARVMD-H080/R1XARVMD-H090/R1X
Cooling capacity[kW]4,55,67,18,09,0
Heating capacity[kW]5,16,38,09,010,0
Power[V~, Hz, Ph]220~240,50/60,1220~240,50/60,1220~240,50/60,1220~240,50/60,1220~240,50/60,1
Nominal power[W]7373106106126
Airflow (high/medium/low)[m3/h]950/850/700950/850/7001300/1100/8501300/1100/8501400/1200/950
Acoustic pressure level (high/medium/low)[dB(A)]40/37/3340/37/3341/39/3641/39/3644/41/39
ESP external static pressure[Pa]50/8050/8050/8050/8050/80
Dimensions (W x D x H)[mm]890x735x290890x735x290890x735x290890x735x290890x735x290
Net wegight[kg]29,529,530,530,532,5
Refrigerant type R410AR410AR410AR410AR410A
Piping dimensionsLiquid[mm (inches)]6,35 (1/4)6,35 (1/4)9,52 (3/8)9,52 (3/8)9,52 (3/8)
Gas[mm (inches)]12,7 (1/2)12,7 (1/2)15,88 (5/8)15,88 (5/8)15,88 (5/8)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)

Model ARVMD-H100/R1XARVMD-H112/R1XARVMD-H125/R1XARVMD-H140/R1XARVMD-H150/R1X
Cooling capacity[kW]10,011,212,514,015,0
Heating capacity[kW]11,212,514,015,017,0
Power[V~, Hz, Ph]220~240,50/60,1220~240,50/60,1220~240,50/60,1220~240,50/60,1220~240,50/60,1
Nominal power[W]126191191220220
Airflow (high/medium/low)[m3/h]1400/1200/9502000/1700/14002000/1700/14002200/1850/15502200/1850/1550
Acoustic pressure level (high/medium/low)[dB(A)]44/41/3945/42/3945/42/3947/43/4147/43/41
ESP external static pressure[Pa]50/8050/8050/8050/8050/80
Dimensions (W x D x H)[mm]890x735x2901250x735x2901250x735x2901250x735x2901250x735x290
Net wegight[kg]32,542,042,042,042,0
Refrigerant type R410AR410AR410AR410AR410A
Piping dimensionsLiquid[mm (inches)]9,52 (3/8)9,52 (3/8)9,52 (3/8)9,52 (3/8)9,52 (3/8)
Gas[mm (inches)]15,88 (5/8)15,88 (5/8)15,88 (5/8)15,88 (5/8)15,88 (5/8)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)
 

High ESP duct units

Model ARVHD-H112/4R1AARVHD-H125/4R1AARVHD-H140/4R1AARVHD-H150/4R1AARVHD-H220/4R1BARVHD-H280/4R1B
Cooling capacity[kW]11,212,514,015,022,428,0
Heating capacity[kW]12,813,315,016,025,031,5
Power[V~, Hz, Ph]220~240,50,1220~240,50,1220~240,50,1220~240,50,1220~240,50,1220~240,50,1
Nominal power[W]60060060060012501250
Airflow (high/medium/low)[m3/h]2000/1600/14002000/1600/14002000/1600/14002000/1600/14004000/3200/26004000/3200/2600
Acoustic pressure level (high/medium/low)[dB(A)]60/57/5160/57/5160/57/5160/57/515555
ESP external static pressure[Pa]196196196196220220
Dimensions (W x D x H)[mm]1200x719x3801200x719x3801200x719x3801200x719x3801350x700x4601350x700x460
Net wegight[kg]565656569191
Refrigerant type R410AR410AR410AR410AR410AR410A
Piping dimensionsLiquid[mm (inches)]9,52 (3/8)9,52 (3/8)9,52 (3/8)9,52 (3/8)12,7 (1/2)12,7 (1/2)
Gas[mm (inches)]19,05 (3/4)19,05 (3/4)19,05 (3/4)19,05 (3/4)22,2 (7/8)22,2 (7/8)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN25DN25

Model ARVHD-H220/NR1DCARVHD-H280/NR1DC
Cooling capacity[kW]22,428,0
Heating capacity[kW]25,031,5
Power[V~, Hz, Ph]220~240,50/60,1220V~240,50/60,1
Nominal power[W]12001200
Airflow (high/medium/low)[m3/h]40004330
Acoustic pressure level (high/medium/low)[dB(A)]5353
ESP external static pressure[Pa]250250
Dimensions (W x D x H)[mm]1350x700x4601350x700x460
Net wegight[kg]9191
Refrigerant type R410AR410A
Piping dimensionsLiquid[mm (inches)]12,712,7
Gas[mm (inches)]22,222,2
Condensate[mm (inches)]DN25DN25

 

Floor/ceiling units

Model ARVCF-H045/4R1AARVCF-H056/4R1AARVCF-H071/4R1AARVCF-H080/4R1A
Cooling capacity[kW]4.55.67.18.0
Heating capacity[kW]5.06.08.010.0
Power[V~, Hz, Ph]220~240,50,1220~240,50,1220~240,50,1220~240,50,1
Nominal power[W]8080140140
Airflow (high/medium/low)[m3/h]950/760/665950/760/6651300/1040/9101500/1200/1050
Acoustic pressure level (high/medium/low)[dB(A)]42/39/3642/39/3645/42/3947/44/41
Dimensions (W x D x H)[mm]929x660x205929x660x2051280x660x2051280x660x205
Net wegight[kg]26263535
Refrigerant type R410AR410AR410AR410A
Piping dimensionsLiquid[mm (inches)]6.35 (1/4)6.35(1/4)9.52(3/8)9.52(3/8)
Gas[mm (inches)]12.7 (1/2)12.7(1/2)15.88(5/8)15.88(5/8)
Condensate[mm (inches)]DN20 (R3/4)DN20(R3/4)DN20(R3/4)DN20(R3/4)

Model ARVCF-H090/4R1AARVCF-H100/4R1AARVCF-H112/4R1AARVCF-H125/4R1AARVCF-H140/4R1A
Cooling capacity[kW]9.010.011.212.514.0
Heating capacity[kW]11.012.012.813.315.0
Power[V~, Hz, Ph]220~240,50,1220~240,50,1220~240,50,1220~240,50,1220~240,50,1
Nominal power[W]140140210210210
Airflow (high/medium/low)[m3/h]1500/1200/10501500/1200/10501800/1440/12601800/1440/12601800/1440/1260
Acoustic pressure level (high/medium/low)[dB(A)]47/44/4147/44/4148/45/4248/45/4248/45/42
Dimensions (W x D x H)[mm]1280x660x2051280x660x2051631x660x2051631x660x2051631x660x205
Net wegight[kg]3535454545
Refrigerant type R410AR410AR410AR410AR410A
Piping dimensionsLiquid[mm (inches)]9.52 (3/8)9.52 (3/8)9.52 (3/8)9.52 (3/8)9.52 (3/8)
Gas[mm (inches)]15.88 (5/8)15.88 (5/8)15.88 (5/8)15.88 (5/8)15.88 (5/8)
Condensate[mm (inches)]DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)DN20 (R3/4)

Capacities are based on the following conditions:
Cooling capacity: indoor temperature 27 ° C (DB dry thermometer) / 19 ° C (wet thermometer WB); outdoor temperature 35 ° C (DB dry thermometer) / 24 ° C (WB wet thermometer).
Heating capacity: indoor temperature 20 ° C (DB dry thermometer); outdoor temperature 7 ° C (DB dry thermometer) / 6 ° C (WB wet thermometer).
Refrigeration piping length: Equivalent installation length: 7.5m; 0 m level difference.
Sound level values measured in an anechoic chamber at 1 meter from the unit and 1.3 meters above the floor.
These functions and specifications are for information purposes only and are subject to change without notice.
The devices contain fluorinated greenhouse gases R410A.