aux
Duct units
Always comfortable and effective cooling - even in large rooms.
Duct units CAD Series

Duct units

CAD Series
AUX-C-(18/24/30/36/42/48/60)CAD

 

  • Compact size - only 245 mm high.Thanks to the extremely flat design, the AUX duct units are perfect for rooms with limited installation space. The small height of the casing - only 245 mm - makes it possible to install the unit even in low ceiling spaces.
  • Hidden air conditioning system. Duct units are designed to be built-in - they offer silent operation and wide range of installation modes. Once installed in the suspended ceiling, they are invisible, and the air is distributed through channels to the vents which can be designed flexibly.

Comfortable and effective cooling anytime- even in large rooms

Efficient and hidden units, giving the greatest freedom in designing the system. Thanks to the extremely flat design, the casing will fit even in low ceiling spaces. Adjustable static pressure up to 160 Pa allows the using long ventilation ducts and the automatic ESP adjustment function guarantees comfortable cooling and heating at all times, regardless of the length of the ducts.

Duct units CAD Series

Factory built-in drain pump

lifting height up to 70 cm

The AUX duct unit can be additionally equipped with a condensate pump, which allows to drain the water condensate up to 70 cm above the drain pan level.

 

Flexible system design

even over long distances

Adjustable static pressure from 0 to 160 Pa allows greater flexibility in designing the installation - it enables using long ventilation ducts.

Flexible installation

two air intake options

The design of the duct unit allows two ways of mounting the air inlet, giving greater freedom in designing the system. As standard, the air inlet is located at the back of the unit. If the room arrangement requires it, the air can also be taken in via the lower air inlet (optional).

Automatic ESP adjustment

comfortable conditions and low noise level

The Automatic Static Pressure Control (ESP) function provides comfortable room conditions with low noise levels. The fan speed and the amount of supplied air are automatically adjusted to the length of the ventilation duct, so as to provide a constant air flow regardless of the length of the pipework.

Technical data

CAD Series
AUX-C-(18/24/30/36)CAD

Model   AUX-C-18CAD AUX-C-24CAD AUX-C-30CAD AUX-C-36CAD
Cooling capacity [kW] 5,00(1,53-5,60) 7,00 (2,16 - 8,20) 8,40 (2,49 - 9,20) 10,55(2,90-13,00)
[Btu/h] 18000 (5200-19100) 24000 (7400 - 28000) 28660 (8490-31390) 36000 (9800 - 44300)
Heating capacity [kW] 5,60 (1,40-6,20) 8,00 (1,98-9,30) 9,00 (2,86 - 9,60) 11,15(2,60-13,50)
[Btu/h] 19100 (4800-21200) 27300 (6800-31700) 30700 (9760 - 32760) 38000 (8800 - 46000)
Power [V~,Hz,Ph] 220-240, 50,1 220-240, 50,1 220-240, 50,1 220-240, 50,1
Power consumption Cooling [kW] 1,55 (0,47-2,30) 2,12(0,67-3,56) 3,09 (0,71 - 3,70) 3,40 (0,71 -4,71)
Heating [kW] 1,49 (0,46 - 2,25) 2,12(0,65-3,62) 2,86 (0,67 - 3,70) 3,45 (0,47-4,13)
Energy consumption Cooling [A] 6,73 (2,25 -10,10) 9,22 (3,21 -15,63) 13,43 (3,09-16,25) 15,00 (3,20-21,50)
Heating [A] 6,80 (2,20 - 9,88) 9,60 (3,11 -15,90) 12,50 (2,91 -16,25) 15,50 (2,43- 18,00)
EER/COP [W/W] 3,23 / 3,76 3,30 / 3,77 2,72/3,15 3,10 / 3,23
SEER /SCOP [W/W] 6,2/4,0 6,1 / 4,0 6,1 / 4,1 6,1 / 4,1
Energy efficiency class Cooling   A++ A++ A++ A++
Heating   A+ A+ A+ A+
Indoor unit   AUX-C-18CAD/I AUX-C-24CAD/I AUX-C-30CAD/I AUX-C-36CAD/I
Fan motor power [W] 200 200 200 300
Fan speed (high/medium/low) [rpm] 1020/915/855 1200/1065/960 1350/1245/1110 1185/1095/1020
Air flow (high/medium/low) [m3/h] 1150/960/840 1400/1190/980 1600/1400/1100 1900/1600/1400
Sound pressure level (high/medium/low) [dB(A)] 43/41/40 44/41/39 46/44/41 44/41/39
Sound power level [dB(A)] 53 55 57 55
Indoor unit dimensions (W x D x H) [mm] 1000 x 700 x 245 1000 x 700 x 245 1000 x 700 x 245 1400x700x245
Indoor unit weight (netto) [kg] 31 32 32 42
Outdoor unit   AUX-C-18CAO AUX-C-24CAO AUX-C-30CAO AUX-C-36CAO
Compressor type    rotacyjna rotacyjna rotacyjna rotacyjna
Air flow (high/medium/low) [m3/h] 2600 3750 3800 4000
Sound pressure level [dB(A)] 55 58 57 57
Sound power level [dB(A)] 64 67 68 66
Dimensions of the outdoor unit (W x D x H) [mm] 800x315x545 900x350x700 970x395x805 970x395x805
Outdoor unit weight (netto) [kg] 37 51 65 72
Refrigerant Type Type   R32 R32 R32 R32
Factory charging [kg] 1,16 1,4 1,60 2,54
Pipe connections (diameter) Liquid [mm (inch)] 6,35 (1/4) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8)
Gas [mm (inch)] 12,7 (1/2) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8)
Condensate [mm (inch)] DN20 (R3/4) DN20 (R3/4) DN20 (R3/4) DN20 (R3/4)
Maximum piping length [m] 30 50 50 65
Maximum level difference [m] 20 25 25 30
Operation range (ambient temperature) Cooling [°C] -15-52 -15-52 -15-52 -15-52
Heating [°C] -22-24 -22-24 -22-24 -22-24
Temperature setting range [°C] 16-32 16-32 16-32 16-32
 
 

Technical data

CAD Series

AUX-C-(42/48/60) CAD

Model   AUX-C-42CAD AUX-C-48CAD AUX-C-60CAD
Cooling capacity [kW] 12,10 (2,90-13,50) 14,00 (4,76-16,50) 16,00 (4,76-17,50)
[Btu/h] 42000 (9800 - 46000) 48000 (16241 - 56298) 55000 (16241 - 59710)
Heating capacity [kW] 13,50 (2,60-15,00) 16,00 (4,78 -16,15) 17,00 (4,78-18,50)
[Btu/h] 46000 (8800 - 51100) 55000 (16309-55104) 58000 (16308-63122)
Power [V-,Hz,Ph] 220-240, 50,1 380-415, 50,3 380-415, 50,3
Power consumption Cooling [kW] 4,43 (0,71 - 5,10) 5,00(1,71 -6,60) 5,88 (1,71 - 6,70)
Heating [kW] 4,60 (0,47 - 4,53) 5,00(1,71 -6,70) 5,60 (1,71 -6,80)
Energy consumption Cooling [A] 19,00 (3,20-22,30) 7,93 (2,47 - 9,53) 9,00 (2,47 - 9,70)
Heating [A] 20,00 (2,43-19,70) 8,23 (2,47 - 9,70) 8,53 (2,47 - 9,83)
EER / COP [W/W] 2,73 / 2,93 2,8 / 3,2 2,72/3,04
SEER /SCOP [W/W] 6,1 / 4,1 6,1 / 4,0 6,1 / 4,0
Energy efficiency class Cooling   A++ A++ A++
Heating   A+ A+ A+
Indoor unit   AUX-C-42CAD/I AUX-C-48CAD/I AUX-C-60CAD/I
Fan motor power [W] 300 300 300
Fan speed (high/medium/low) [rpm] 1185/1095/1020 1425/1305/1200 1425/1305/1200
Air flow (high/medium/low) [m3/h] 1900/1600/1400 2300/2000/1700 2300/2000/1700
Sound pressure level (high/medium/low) [dB(A)] 44/41/39 52/49/47 52/49/47
Sound power level [dB(A)] 55 64 64
Indoor unit dimensions (W x D x H) [mm] 1400x700x245 1400x700x245 1400x700x245
Indoor unit weight (netto) [kg] 42 42 42
Outdoor unit   AUX-C-42CAO AUX-C-48CAO AUX-C-60CAO
Compressor type    rotacyjna rotacyjna rotacyjna
Air flow (high/medium/low) [m3/h] 4200 7200 7200
Sound pressure level [dB(A)] 57 60 60
Sound power level [dB(A)] 66 70 70
Dimensions of the outdoor unit (W x D x H) [mm] 970x395x805 940x370x1325 940x370x1325
Outdoor unit weight(netto) [kg] 72 92 92
Refrigerant Type Type   R32 R32 R32
Factory charging [kg] 2,54 3,6 3,6
Pipe connections (diameter) Liquid [mm (inch)] 9,52 (3/8) 9,52 (3/8) 9,52 (3/8)
Gas [mm (inch)] 15,88 (5/8) 19,05(3/4) 19,05(3/4)
Condensate [mm (inch)] DN20 (R3/4) DN20 (R3/4) DN20 (R3/4)
Maximum piping length [m] 65 65 65
Maximum level difference [m] 30 30 30
Operation range (ambient temperature) Cooling [°C] -15-52 -15-52 -15-52
Heating [°C] -22-24 -22-24 -22-24
Temperature setting range [°C] 16-32 16-32 16-32

 

High-quality inverter compressor

guarantee of energy efficiency and reliability

The inverter rotary compressor used in AUX air conditioners guarantees reliable and efficient operation of the devices as well as the highest energy efficiency parameters. It also reduces energy costs and noise level. Durable, high-quality materials used in the construction of the compressor provide long and failure-free operation.

Duct units CAD Series
Duct units CAD Series

R32 refrigerant

ecological, highly effective, safe

All AUX air conditioning units of CAC series operate using the newest ecological refrigerant R32, which, comparing to the commonly used R41OA refrigerant, is characterized by higher efficiency and a lower greenhouse effect. It also does not damage the ozone layer.

High energy efficiency

guarantee of energy-saving operation

Owing to the use of a highly efficient DC inverter compressor, adjustable fan motor and advanced 180 ° sine wave vector control technology, commercial AUX systems achieve high energy efficiency parameters, providing reliable, efficient operation with low energy consumption. All CAC air conditioners are class A ++ in cooling and A + in heating mode.

Duct units CAD Series
Duct units CAD Series

A wide range operation

Reliable operation even in adverse weather conditions

AUX commercial air conditioning systems are characterized by reliable, stable operation even in extreme ambient temperatures. Owing to the use of modern technologies and high-quality components, AUX devices operate in a wide range of outdoor temperatures, i.e. from -15 ° C to 52 ° C in cooling mode and from -22 ° C to 24 ° C in heating mode, providing a high level of comfort in the room in all the seasons of the year.

Anti-corrosion casing of the outdoor unit

Longer life and better aesthetics

The casing of the outdoor unit has been covered with a number of protective layers, protecting it against insects, rodents, moisture, dust and fire. It guarantees a long lifespan of the device and an better aesthetics after many years of exposure to adverse weather conditions.

Duct units CAD Series
Duct units CAD Series

Intelligent defrosting

Effective operation at low ambient temperatures

The air conditioner activates the defrosting mode only when necessary and only for the time needed to defrost the heat exchanger, which allows the unit to operate almost continuously in heating mode. The intelligent defrosting system used in AUX air conditioners improves the energy efficiency of the devices by 5% and increases the heating efficiency as much as 20% at low ambient temperatures.

Automatic restart

Setting memory in the event of a power failure

In the event of a power failure, the device records the last settings and restarts after resuming the power supply, automatically restoring the previously set operating mode

Duct units CAD Series
Duct units CAD Series

Outdoor unit drip tray heater

Efficient operation in heating mode

Outdoor units of AUX commercial air conditioner series are equipped with a  drip tray heaters, which allow the devices to operate efficiently in heating mode even in severe frosts, preventing the heat exchanger from icing.

180 sine wave control

Smooth and efficient operation of the compressor

The DC inverter compressor uses 180 ° sine wave control. The solution makes the compressor motor run smoothly and the efficiency increases significantly.

Duct units CAD Series

Features and functions

AUX Air Conditioner functions
R32 refrigerant
AUX Air Conditioner functions
Inverter technology
AUX Air Conditioner functions
Automatic restart
AUX Air Conditioner functions
Hydrophyte aluminum fan vanes
AUX Air Conditioner functions
Intelligent defrosting function
AUX Air Conditioner functions
Fast cooling / heating mode
AUX Air Conditioner functions
Cooling at low temperatures
AUX Air Conditioner functions
Durable air filter
AUX Air Conditioner functions
Wired controller
AUX Air Conditioner functions
Cooling mode
AUX Air Conditioner functions
Heating mode
klimatyzator aux
Heating at -22oC
AUX Air Conditioner functions
Fan mode
AUX Air Conditioner functions
Drying mode
AUX Air Conditioner functions
Auto mode
AUX Air Conditioner functions
Optional drain pump
Wireless controller
Optional wired controller