The AUX heat pump is a versatile device designed to work with a wide range of heat receivers, such as: floor heating system, radiators or fan coil units.
The AUX Group, as one of the leading manufacturers of advanced air conditioning and heat pump systems, approaches sustainable development very seriously. Caring for the environment is one of the major aspects of sustainable development. The policy of the AUX brand is based on the idea of careful exploitation of natural resources, so that both present and future generations can live in prosperity. Teams of qualified engineers working at AUX R&D centres around the world invent energy-saving, intelligent and ecological tech solutions, which are used in production processes to support the concept of sustainable development and provide high-quality and clean air.
A heat pump uses as much as 75% of free energy available in the air and electricity makes up for 25%. Actually, it means that the device collects heat that is present in the air and transfers is to the building consuming a small amount of electricity. Energy efficiency of a heat is determined by the coefficient of performance (COP) which determines ratio of the amount of heat supplied to the amount of electricity consumed. The higher the COP, the greater the energy efficiency. The higher the energy efficiency indicator, the higher the efficiency and consequently – the savings. A heat pump is one of the most economical and environmentally friendly heating systems.
The vast majority of air-to-water heat pumps are classified as renewable energy sources and are currently considered the most efficient heating solution. An air-to-water heat pump is a device that uses heat accumulated in the air for heating or cooling space and for domestic hot water system. Against all appearances, the way a heat pump works is not complicated and it uses a well-known mechanism that can be found in refrigerators for example. The most important parts of a heat pump are: the compressor, expansion valve, condenser and evaporator. The whole process is possible thanks to physical properties of refrigerant. Refrigerant is a liquid that circulates in the close loop system. It boils at low pressure and low temperature and this way it absorbs heat from the environment. Then pressure and temperature are increased in the system by a compressor and the refrigerant changes into gas and next it moves to a condenser and releases heat to the system. Afterwards liquid refrigerant passes through the expansion valve where the pressure and temperature drop and the process starts again. If a heat pump provides cooling, the process is reversed – refrigerant absorbs heat from water and removes it outside.
Coefficient of Performance
Coefficient of performance, which determines the ratio of the amount of thermal energy supplied to the heat pump to the amount of energy consumed by it. If the COP of a heat pump is 5, it means that the device consumes 1kW of electricity to provide 5kW of heat.
Seasonal Coefficient of Performance
Seasonal coefficient of performance allows you to calculate the amount of electricity consumed by a device during the year or heating season. It allows to calculate easily the cost of heating a building by a heat pump.
Energy Efficiency Ratio
Coefficient of performance determines the ratio of the amount of cooling energy supplied to a heat pump to the amount of energy consumed by it. If the EER for of heat pump is 5, it means that the device consumes 1kW of electricity to provide 5kW of cooling.
Seasonal Energy Efficiency Ratio
Seasonal coefficient of performance allows you to calculate the amount of electricity consumed by a heat pump during the year or a season. It allows to calculate easily the cost of cooling a building by a heat pump.
Air-to-water heat pumps work with the following heat receivers: fan coil units, radiators or floor heating system. However, the use of low-temperature heat receivers works best in terms of efficiency. Radiant heating is characterized by large surface and as a consequence there is no need for high temperature in the system contrary to compact heat sources.
It heats and cools the building and supplies domestic hot water.
No risk of fire, explosion or carbon monoxide poisoning.
Dedicated to recently built and additionally insulated buildings.
Approximate installation time carried out by an experienced company is 1 to 3 days.
There is no need to clean, start fire or constantly watch the unit.
While operating it does not emit harmful substances into the environment.
Quiet operation provides users with high comfort.
No need to install radiators which often affect the aesthetics of the interior.
Free energy obtained the air and the possibility of connecting to a photovoltaic system.
It is estimated that the average lifespan of a heat pump is 20 years.
A heat pump works with low-temperature floor, wall and ceiling heating systems.
It uses R32 refrigerant which is currently the most environmentally friendly.
It provides domestic hot water reaching temperature up to 60°C.
Inverter technology allows smooth efficiency control without lowering the efficiency of the device.
A +++ energy efficiency is a guarantee of energy efficiency.
The Fast DHW function will satisfy the need for hot water very quickly.
High sterilization temperature provides 99% effectiveness in eliminating legionella bacteria that are able to multiply in hot water tanks when water is not used for a long time.
The heat pump defines and sets the optimum water temperature for the highest comfort.
Eco mode saves energy up to 50%.
The holiday function protects the device against possible damage caused by frost for example.
Quiet operation of the outdoor unit with the noise level below 45dB and the indoor unit below 31dB.
Heat pumps marked with SG Ready label are equipped with control system that allows to connect a single heat pump into a smart grid.
There is no risk of explosion or releasing toxic carbon monoxide while heating a house by a heat pump. No carbon dioxide is released during operation of a heat pump.
The AUX heat pump is KEYMARK certified confirming the compliance of products and services with European standards and hygienic certification.
A heat pump is a device that does not emit any pollutants into the environment which makes it an ecological alternative to traditional heating methods.
A heat pump is almost a maintenance-free system so it saves a lot of time.
Installation of an air-source heat pump is relatively quick and easy. It usually takes 2 to 3 days.
It works with various heat receivers (floor heating, radiators, fan coil units) and it can operate in combined systems with other heat sources such as gas furnace or electric heaters.
The operating cost of a heat pump is really low. This is primarily due to the high energy efficiency of this device.
The Wi-Fi module provides easy and convenient control with the app.
Model name | ACHP-HC4/4R3HA | ACHP-H06/4R3HA | ACHP-H08/4R3HA | ACHP-H10/4R3HA | ACHP-H12/5R3HA | ACHP-H14/5R3HA | ACHP-H16/5R3HA | ||
---|---|---|---|---|---|---|---|---|---|
Outdoor unit | ACHP-H04/4R3HA-O | ACHP-H06/4R3HA-O | ACHP-H08/4R3HA-O | ACHP-H10/4R3HA-O | ACHP-H12/5R3HA-O | ACHP-H14/5R3HA-O | ACHP-H16/5R3HA-O | ||
Indoor unit | ACHP-H04/4R3HA-I | ACHP-H06/4R3HA-I | ACHP-H08/5R3HA-I | ACHP-H10/5R3HA-I | ACHP-H12/5R3HA-I | ACHP-H14/5R3HA-I | ACHP-H16/5R3HA-I | ||
Heating (A7/W35) (1) | Capacity | kW | 4,3 | 6,25 | 8,4 | 10 | 12,2 | 14,5 | 16,1 |
Power consumption | kW | 0,83 | 1,3 | 1,62 | 2 | 2,44 | 3,08 | 3,57 | |
COP | 5,2 | 5 | 5,2 | 5 | 5 | 4,71 | 4,51 | ||
Heating (A7/W55) (2) | Capacity | kW | 4,36 | 6,4 | 8,3 | 10 | 12 | 14 | 16,1 |
Power consumption | kW | 1,47 | 2,13 | 2,60 | 3,23 | 3,86 | 4,67 | 5,53 | |
COP | 2,96 | 3 | 3,19 | 3,1 | 3,11 | 3 | 2,91 | ||
Cooling (A35/W18) (3) | Capacity | kW | 4,5 | 6,6 | 8,45 | 10 | 12 | 13,6 | 15 |
Power consumption | kW | 0,81 | 1,35 | 1,67 | 2,08 | 3 | 3,78 | 4,41 | |
EER | 5,56 | 4,9 | 5,06 | 4,8 | 4 | 3,6 | 3,4 | ||
Cooling (A35/W7) (4) | Capacity | kW | 4,75 | 7,05 | 7,45 | 8,3 | 11,7 | 12,8 | 14 |
Power consumption | kW | 1,40 | 2,35 | 2,20 | 2,52 | 4,3 | 5,00 | 5,7 | |
EER | 3,4 | 3 | 3,39 | 3,3 | 2,75 | 2,56 | 2,46 | ||
Seasonal Energy Efficiency Class: ogrzewanie (6) | LWT 35°C | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | |
LWT 55°C | A++ | A++ | A++ | A++ | A++ | A++ | A++ | ||
SCOP (6) | LWT 35°C | 4,86 | 4,96 | 5,22 | 5,2 | 4,82 | 4,71 | 4,63 | |
LWT 55°C | 3,32 | 3,53 | 3,37 | 3,5 | 3,46 | 3,48 | 3,43 | ||
Power | Outdoor unit | V/~/Hz | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 220-240/1/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 |
Indoor unit | V/~/Hz | 220-240/1/50 | 220-240/1/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Maximum circuit breaker | A | 18 | 18 | 19 | 19 | 14 | 14 | 14 | |
Compressor | Type | – | Double rotary DC Inverter | Double rotary DC Inverter | Double rotary DC Inverter | Double rotary DC Inverter | Double rotary DC Inverter | Double rotary DC Inverter | Double rotary DC Inverter |
Outdoor unit fan | Motor type | – | Brushless DC motor | Brushless DC motor | Brushless DC motor | Brushless DC motor | Brushless DC motor | Brushless DC motor | Brushless DC motor |
Number of fans | – | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Refrigerant Typee (R32) | Quantity | kg | 1,10 | 1,25 | 1,65 | 1,65 | 1,84 | 1,84 | 1,84 |
Expansion valve type | – | Electronic | Electronic | Electronic | Electronic | Electronic | Electronic | Electronic | |
Cooling system | Liquid / gas pipe diameter | mm | 09.52/15.9 | 09.52/15.9 | 09.52/15.9 | 09.52/15.9 | 09.52/15.9 | 09.52/15.9 | 09.52/15.9 |
Piping length min/max | m | 2/30 | 2/30 | 2/30 | 2/30 | 2/30 | 2/30 | 2/30 | |
Height difference in the system | Outdoor unit above/below | m | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Sound pressure level (1 m) | Outdoor unit | dB | 43 | 44 | 45 | 48 | 49 | 50 | 54 |
Indoor unit | dB | 28 | 28 | 29 | 29 | 31 | 31 | 31 | |
Net dimensions (LxHxW) | Outdoor unit | mm | 350x700x900 | 350x700x900 | 395x805x970 | 395x805x970 | 420x860x990 | 420x860x990 | 420x860x990 |
Indoor unit | mm | 420x790x270 | 420x790x270 | 420x790x270 | 420x790x270 | 420x790x270 | 420x790x270 | 420x790x270 | |
Packaging dimensions (LxHxW) | Outdoor unit | mm | 430x770x1020 | 430x770x1020 | 495x895x1105 | 495x895x1105 | 530x880x1085 | 530x880x1085 | 530x880x1085 |
Indoor unit | mm | 515x985x355 | 515x985x355 | 515x985x355 | 515x985x355 | 515x985x355 | 515x985x355 | 515x985x355 | |
Net/gross weight | Outdoor unit | kg | 51/55 | 51/55 | 65/69 | 65/69 | 88/94 | 88/94 | 88/94 |
Indoor unit | kg | 38/44 | 38/44 | 39/45 | 39/45 | 39/45 | 39/45 | 39/45 | |
Operation range at ambient temperatures | Cooling | “C | 10 ~ 48 | 10 ~ 48 | 10 ~ 48 | 10 ~ 48 | 10 ~ 48 | 10 ~ 48 | 10 ~ 48 |
Heating | “C | -25 ~ 35 | -25 ~ 35 | -25 ~ 35 | -25 ~ 35 | -25 ~ 35 | -25 ~ 35 | -25 ~ 35 | |
DHW | “C | -25 ~ 43 | -25 ~ 43 | -25 ~ 43 | -25 ~ 43 | -25 ~ 43 | -25 ~ 43 | -25 ~ 43 | |
Water temperature range | Cooling | “C | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 | 5 ~ 25 |
Heating | “C | 25 ~ 65 | 25 ~ 65 | 25 ~ 65 | 25 ~ 65 | 25 ~ 65 | 25 ~ 65 | 25 ~ 65 | |
DHW | “C | 30 ~ 60 | 30 ~ 60 | 30 ~ 60 | 30 ~ 60 | 30 ~ 60 | 30 ~ 60 | 30 ~ 60 | |
Water loop | |||||||||
Water connection | inches | R1″ | R1″ | R1″ | R1″ | R1″ | R1″ | R1″ | |
Safety valve setting | MPa | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | |
Minimum water flow | m3/h | 0,36 | 0,36 | 0,36 | 0,36 | 0,6 | 0,6 | 0,6 | |
Expansion vessel | Capacity | L | 8 | 8 | 8 | 8 | 8 | 8 | 8 |
Max water pressure | MPa | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | 0,3 | |
Water exchanger type | – | Flat plate | Flat plate | Flat plate | Flat plate | Flat plate | Flat plate | Flat plate | |
Electric Flow-through heater | kW | 3 | 3 | 9 | 9 | 9 | 9 | 9 | |
Water pump head height | m | 9,5 | 9,5 | 9,5 | 9,5 | 9,5 | 9,5 | 9,5 |