AUX Split heat pump

The AUX heat pump is a versatile device designed to work with a wide range of heat receivers, such as: floor heating system, radiators or fan coil units.

SUSTAINABLE DEVELOPMENT

The AUX Group, as one of the leading manufacturers of advanced air conditioning and heat pump systems, approaches sustainable development very seriously. Caring for the environment is one of the major aspects of sustainable development. The policy of the AUX brand is based on the idea of careful exploitation of natural resources, so that both present and future generations can live in prosperity. Teams of qualified engineers working at AUX R&D centres around the world invent energy-saving, intelligent and ecological tech solutions, which are used in production processes to support the concept of sustainable development and provide high-quality and clean air.

CARING FOR A BETTER TOMORROW

NATURAL ENERGY

A heat pump uses as much as 75% of free energy available in the air and electricity makes up for 25%. Actually, it means that the device collects heat that is present in the air and transfers is to the building consuming a small amount of electricity. Energy efficiency of a heat is determined by the coefficient of performance (COP) which determines ratio of the amount of heat supplied to the amount of electricity consumed. The higher the COP, the greater the energy efficiency. The higher the energy efficiency indicator, the higher the efficiency and consequently – the savings. A heat pump is one of the most economical and environmentally friendly heating systems.

HOW DOES A HEAT PUMP WORK?

The vast majority of air-to-water heat pumps are classified as renewable energy sources and are currently considered the most efficient heating solution. An air-to-water heat pump is a device that uses heat accumulated in the air for heating or cooling space and for domestic hot water system. Against all appearances, the way a heat pump works is not complicated and it uses a well-known mechanism that can be found in refrigerators for example. The most important parts of a heat pump are: the compressor, expansion valve, condenser and evaporator. The whole process is possible thanks to physical properties of refrigerant. Refrigerant is a liquid that circulates in the close loop system. It boils at low pressure and low temperature and this way it absorbs heat from the environment. Then pressure and temperature are increased in the system by a compressor and the refrigerant changes into gas and next it moves to a condenser and releases heat to the system. Afterwards liquid refrigerant passes through the expansion valve where the pressure and temperature drop and the process starts again. If a heat pump provides cooling, the process is reversed – refrigerant absorbs heat from water and removes it outside.

COP

Coefficient of Performance

Coefficient of performance, which determines the ratio of the amount of thermal energy supplied to the heat pump to the amount of energy consumed by it. If the COP of a heat pump is 5, it means that the device consumes 1kW of electricity to provide 5kW of heat.

SCOP

Seasonal Coefficient of Performance

Seasonal coefficient of performance allows you to calculate the amount of electricity consumed by a device during the year or heating season. It allows to calculate easily the cost of heating a building by a heat pump.

EER

Energy Efficiency Ratio

Coefficient of performance determines the ratio of the amount of cooling energy supplied to a heat pump to the amount of energy consumed by it. If the EER for of heat pump is 5, it means that the device consumes 1kW of electricity to provide 5kW of cooling.

SEER

Seasonal Energy Efficiency Ratio

Seasonal coefficient of performance allows you to calculate the amount of electricity consumed by a heat pump during the year or a season. It allows to calculate easily the cost of cooling a building by a heat pump.

THE HIGHER SCOP AND SEER, THE LOWER ELECTRICITY BILLS

HEAT PUMP WORKS WITH HEAT RECEIVERS

Air-to-water heat pumps work with the following heat receivers: fan coil units, radiators or floor heating system. However, the use of low-temperature heat receivers works best in terms of efficiency. Radiant heating is characterized by large surface and as a consequence there is no need for high temperature in the system contrary to compact heat sources.

WHY AUX HEAT PUMP?

Complete heating system

It heats and cools the building and supplies domestic hot water.

Full security

No risk of fire, explosion or carbon monoxide poisoning.

Versatile use

Dedicated to recently built and additionally insulated buildings.

Easy and quick assembly

Approximate installation time carried out by an experienced company is 1 to 3 days.

Maintenance-free

There is no need to clean, start fire or constantly watch the unit.

Ecology

While operating it does not emit harmful substances into the environment.

Peace and quiet

Quiet operation provides users with high comfort.

Aesthetics

No need to install radiators which often affect the aesthetics of the interior.

Savings

Free energy obtained the air and the possibility of connecting to a photovoltaic system.

Long lifespan

It is estimated that the average lifespan of a heat pump is 20 years.

FEATURES AND FUNCTIONS OF AUX HEAT PUMP

 Surface heating

A heat pump works with low-temperature floor, wall and ceiling heating systems.

R32 refrigerant

It uses R32 refrigerant which is currently the most environmentally friendly.

Domestic hot water up to 60°C

It provides domestic hot water reaching temperature up to 60°C.

Inverter technology

Inverter technology allows smooth efficiency control without lowering the efficiency of the device.

Energy efficiency A+++

A +++ energy efficiency is a guarantee of energy efficiency.

 Fast domestic hot water

The Fast DHW function will satisfy the need for hot water very quickly.

Sterilization at 65°C

High sterilization temperature provides 99% effectiveness in eliminating legionella bacteria that are able to multiply in hot water tanks when water is not used for a long time.

Water temperature auto-adaptation

The heat pump defines and sets the optimum water temperature for the highest comfort.

ECO mode

Eco mode saves energy up to 50%.

Holiday mode

The holiday function protects the device against possible damage caused by frost for example.

Quiet operation

Quiet operation of the outdoor unit with the noise level below 45dB and the indoor unit below 31dB.

SG Ready

Heat pumps marked with SG Ready label are equipped with control system that allows to connect a single heat pump into a smart grid.

Security

There is no risk of explosion or releasing toxic carbon monoxide while heating a house by a heat pump. No carbon dioxide is released during operation of a heat pump.

Certificates

The AUX heat pump is KEYMARK certified confirming the compliance of products and services with European standards and hygienic certification.

Emission-free

A heat pump is a device that does not emit any pollutants into the environment which makes it an ecological alternative to traditional heating methods.

Maintenance-free

A heat pump is almost a maintenance-free system so it saves a lot of time.

Quick installation

Installation of an air-source heat pump is relatively quick and easy. It usually takes 2 to 3 days.

Versatile use

It works with various heat receivers (floor heating, radiators, fan coil units) and it can operate in combined systems with other heat sources such as gas furnace or electric heaters.

Low operating cost

The operating cost of a heat pump is really low. This is primarily due to the high energy efficiency of this device.

Wi-Fi module

The Wi-Fi module provides easy and convenient control with the app.

Technical data

Model name ACHP-HC4/4R3HA ACHP-H06/4R3HA ACHP-H08/4R3HA ACHP-H10/4R3HA ACHP-H12/5R3HA ACHP-H14/5R3HA ACHP-H16/5R3HA
Outdoor unit ACHP-H04/4R3HA-O ACHP-H06/4R3HA-O ACHP-H08/4R3HA-O ACHP-H10/4R3HA-O ACHP-H12/5R3HA-O ACHP-H14/5R3HA-O ACHP-H16/5R3HA-O
Indoor unit ACHP-H04/4R3HA-I ACHP-H06/4R3HA-I ACHP-H08/5R3HA-I ACHP-H10/5R3HA-I ACHP-H12/5R3HA-I ACHP-H14/5R3HA-I ACHP-H16/5R3HA-I
Heating (A7/W35) (1) Capacity kW 4,3 6,25 8,4 10 12,2 14,5 16,1
Power consumption kW 0,83 1,3 1,62 2 2,44 3,08 3,57
COP   5,2 5 5,2 5 5 4,71 4,51
Heating (A7/W55) (2) Capacity kW 4,36 6,4 8,3 10 12 14 16,1
Power consumption kW 1,47 2,13 2,60 3,23 3,86 4,67 5,53
COP   2,96 3 3,19 3,1 3,11 3 2,91
Cooling (A35/W18) (3) Capacity kW 4,5 6,6 8,45 10 12 13,6 15
Power consumption kW 0,81 1,35 1,67 2,08 3 3,78 4,41
EER   5,56 4,9 5,06 4,8 4 3,6 3,4
Cooling (A35/W7) (4) Capacity kW 4,75 7,05 7,45 8,3 11,7 12,8 14
Power consumption kW 1,40 2,35 2,20 2,52 4,3 5,00 5,7
EER   3,4 3 3,39 3,3 2,75 2,56 2,46
Seasonal Energy Efficiency Class: ogrzewanie (6) LWT 35°C   A+++ A+++ A+++ A+++ A+++ A+++ A+++
LWT 55°C   A++ A++ A++ A++ A++ A++ A++
SCOP (6) LWT 35°C   4,86 4,96 5,22 5,2 4,82 4,71 4,63
LWT 55°C   3,32 3,53 3,37 3,5 3,46 3,48 3,43
Power Outdoor unit V/~/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50
Indoor unit V/~/Hz 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
Maximum circuit breaker   A 18 18 19 19 14 14 14
Compressor Type Double rotary DC Inverter Double rotary DC Inverter Double rotary DC Inverter Double rotary DC Inverter Double rotary DC Inverter Double rotary DC Inverter Double rotary DC Inverter
Outdoor unit fan Motor type Brushless DC motor Brushless DC motor Brushless DC motor Brushless DC motor Brushless DC motor Brushless DC motor Brushless DC motor
Number of fans 1 1 1 1 1 1 1
Refrigerant Typee (R32) Quantity kg 1,10 1,25 1,65 1,65 1,84 1,84 1,84
Expansion valve type   Electronic Electronic Electronic Electronic Electronic Electronic Electronic
Cooling system Liquid / gas pipe diameter mm 09.52/15.9 09.52/15.9 09.52/15.9 09.52/15.9 09.52/15.9 09.52/15.9 09.52/15.9
Piping length min/max m 2/30 2/30 2/30 2/30 2/30 2/30 2/30
Height difference in the system Outdoor unit above/below m 20 20 20 20 20 20 20
Sound pressure level (1 m) Outdoor unit dB 43 44 45 48 49 50 54
Indoor unit dB 28 28 29 29 31 31 31
Net dimensions (LxHxW) Outdoor unit mm 350x700x900 350x700x900 395x805x970 395x805x970 420x860x990 420x860x990 420x860x990
Indoor unit mm 420x790x270 420x790x270 420x790x270 420x790x270 420x790x270 420x790x270 420x790x270
Packaging dimensions (LxHxW) Outdoor unit mm 430x770x1020 430x770x1020 495x895x1105 495x895x1105 530x880x1085 530x880x1085 530x880x1085
Indoor unit mm 515x985x355 515x985x355 515x985x355 515x985x355 515x985x355 515x985x355 515x985x355
Net/gross weight Outdoor unit kg 51/55 51/55 65/69 65/69 88/94 88/94 88/94
Indoor unit kg 38/44 38/44 39/45 39/45 39/45 39/45 39/45
Operation range at ambient temperatures Cooling “C 10 ~ 48 10 ~ 48 10 ~ 48 10 ~ 48 10 ~ 48 10 ~ 48 10 ~ 48
Heating “C -25 ~ 35 -25 ~ 35 -25 ~ 35 -25 ~ 35 -25 ~ 35 -25 ~ 35 -25 ~ 35
DHW “C -25 ~ 43 -25 ~ 43 -25 ~ 43 -25 ~ 43 -25 ~ 43 -25 ~ 43 -25 ~ 43
Water temperature range Cooling “C 5 ~ 25 5 ~ 25 5 ~ 25 5 ~ 25 5 ~ 25 5 ~ 25 5 ~ 25
Heating “C 25 ~ 65 25 ~ 65 25 ~ 65 25 ~ 65 25 ~ 65 25 ~ 65 25 ~ 65
DHW “C 30 ~ 60 30 ~ 60 30 ~ 60 30 ~ 60 30 ~ 60 30 ~ 60 30 ~ 60
Water loop
Water connection inches R1″ R1″ R1″  R1″  R1″ R1″ R1″
Safety valve setting MPa 0,3 0,3 0,3 0,3 0,3 0,3 0,3
Minimum water flow m3/h 0,36 0,36 0,36 0,36 0,6 0,6 0,6
Expansion vessel Capacity L 8 8 8 8 8 8 8
Max water pressure MPa 0,3 0,3 0,3 0,3 0,3 0,3 0,3
Water exchanger type Flat plate Flat plate Flat plate Flat plate Flat plate Flat plate Flat plate
Electric Flow-through heater kW 3 3 9 9 9 9 9
Water pump head height m 9,5 9,5 9,5 9,5 9,5 9,5 9,5
We value your privacy