Q-Smart series air conditioners are distinguished by their perfect design refined in every detail. Two attractive color versions, designed according to the latest interior trends, will perfectly fit into elegant interiors, subtly emphasizing their style.
The Q-Smart air conditioner is distinguished by a perfect design, refined in every detail, designed according to the latest interior trends. It will perfectly fit into elegant interiors, subtly emphasizing their style.
The high quality and aesthetics combined with the slim shape of the Q-Smart air conditioners make them fit perfectly any interior style. They can also be an elegant and discreet decoration.
The elegant, graphite casing imitating chrome silver is an offer for those who seek extraordinary colour modes. This model will make a distinctive element that will create the interior atmosphere.
The best models of the Q-Smart series are equipped with UV lamps that guarantee clean and healthy air. UV sterilization effectively cleans the air by eliminating viruses, funghi and microbes. This function is especially recommended for those who suffer from allegry and people susceptible to infections. The temperature of the evaporator piping is kept at the level of 57 ℃ for some time to ensure the best sterilization effect.
This function allows to maintain a constant temperature of +8 °C in heating mode in winter, which prevents the room from cooling down.
Why R32?
As standard the Q-Smart series air conditioners are equipped with a built-in WI-FI module with a weekly programmer. WI-FI is a convenient solution for smartphone, tablet and computer users, enabling air conditioning to be controlled remotely 24h a day.
The application contains numerous functions, i.e. a timer, so there is no need for additional drivers. Controlling the air conditioner through the app is simple and convenient.
Silent mode
Exceptionally quiet operation mode in which the indoor unit of the air conditioner operates at a reduced sound pressure level, ensuring optimal conditions without excessive noise.
„I FEEL” function
Intelligent “I FEEL” temperature interpreting enables perfect adjustment of the temperature to the conditions in the room.
Night mode
Automatic temperature control during sleep. The air conditioner increases the set temperature by 1° C per hour during the first two hours of operation in cooling mode (in heating mode it lowers the temperature at the same rate). For the next 5 hours, it keeps the temperature constant, after which the air conditioner turns off.
Heating mode
The heating mode allows you to use the air conditioner all year round, even in the cooler months. Thanks to the heat pump, the device can heat the air in the room, being an alternative to traditional heating systems.
Drying mode
In the drying mode, the air conditioner lowers the humidity level in the room to the optimum value by automatically adjusting the temperature and airflow rate to achieve the best conditions. This prevents the growth of fungi, mold and bacteria.
Model | AUX-09QB | AUX-12QB | AUX-18QB | AUX-24QB | ||
---|---|---|---|---|---|---|
Cooling capacity | [kW] | 2,7 (0,60 – 3,80) | 3,50(0,80-4,10) | 5,40(1,30-5,80) | 6,70 (1,80 – 7,40) | |
Heating capacity | [kW] | 3,00 (0,80 – 4,20) | 3,80(1,00- 4,10) | 5,60 (1,30-6,00) | 7,20 (1,80 – 8,20) | |
Power | [V~,Hz,Ph] | 220-240, 50,1 | 220-240, 50,1 | 220-240, 50,1 | 220-240, 50,1 | |
Operating voltage | Cooling | [A] | 3,80 | 5,60 | 7,50 | 10,00 |
Heating | [A] | 4,10 | 4,90 | 7,00 | 9,50 | |
Energy consumption | Cooling | [W] | 800 | 1180 | 1700 | 2200 |
Heating | [W] | 850 | 1100 | 1600 | 2200 | |
Maximum power consumption | [A] | 9,5 | 9,5 | 12,0 | 16,0 | |
Energy consumption | [W] | 1900 | 1900 | 2400 | 3400 | |
SEER/SCOP | [W/W] | 6,1 / 4,00 | 6,1 /4,00 | 7,3 / 4,3 | 6,1 / 4,0 | |
Energy efficiency class | Cooling | A++ | A++ | A++ | A++ | |
Heating | A+ | A+ | A+ | A+ | ||
Indoor unit | AUX-09QB/I | AUX-12QB/I | AUX-18QB/I | AUX-24QB/I | ||
Air flow | [m3/h] | 600 | 600 | 950 | 1300 | |
Sound pressure level | [d B(A)] | 38/31/27/22/19 | 38/32/29/23/20 | 41/32/31/26/23 | 38/36/33/31/23 | |
Sound power level | [d B(A)] | 44/40/39/31/24 | 44/40/36/32/23 | 43/40/37/35/30 | 48/43/40/37/28 | |
Indoor unit dimensions | [mm] | 761 X 296 X 198 | 761 X 296 X 198 | 960x315x220 | 1089x327x225 | |
Indoor unit weight | [kg] | 7,5 | 7,5 | 11,0 | 12,5 | |
Outdoor unit | AUX-09QB/O | AUX-12QB/O | AUX-18QB/O | AUX-24QB/O | ||
Refrigerant Typee | Type | R32 | R32 | R32 | R32 | |
Factory charge (up to 5 m) | [g] | 560 | 560 | 1030 | 1300 | |
Additional refrigerant charge | [g/m] | 15 | 15 | 20 | 30 | |
Sound pressure level | [d B(A)] | 52 | 52 | 56 | 58 | |
Sound power level | [d B(A)] | 64 | 64 | 62 | 66 | |
Dimensions of the outdoor unit | [mm] | 708 X 538 X 283 | 708 X 538 X 283 | 785x555x300 | 900 X 700 X 350 | |
Unit weightzewnętrznej | [kg] | 22,5 | 22,5 | 28 | 39 | |
Operation range (ambient temperature) | Cooling Heating | [°С] [°С] | -10 -22 | -10 -22 | -10 -22 | -10 -22 |
Pipe connections (diameter) | Liquid | [mm (inch)] | 1/4 | 1/4 | 1/4 | 1/4 |
Gas | [mm (inch)] | 3/8 | 3/8 | 1/2 | 5/8 | |
Condensate | [mm (inch)] | 16 | 16 | 16 | 18 | |
Maximum piping length | [m] | 20 | 20 | 20 | 25 | |
Maximum level difference | [m] | 10 | 10 | 10 | 15 |