aux
Cassette units
The line is dedicated to people who appreciate a combination of sophisticated style and functionality.
Cassette units - C Series | Multi-Split System

Cassette units

C Series
AUX-C-(09/12/18/24)CAC

  • Fresh air intake for even higher comfortThe fresh air inlet allows the supply of fresh air to the room - the air conditioner works as ventilation system improving the comfort and quality of air inside the building.
  • 360° perimeter airflow functionOwing to the specially designed decorative panel and the 360 ​​° airflow function, the air is evenly distributed in all the space of the room.

Efficient and comfortable cooling of large commercial spaces

Quiet and efficient AUX cassette units are perfect for commercial interiors with a suspended ceiling - offices, conference rooms, restaurants and commercial spaces. Thanks to the 360 ​​° circumferential airflow technology and the quick cooling / heating function, they can provide comfortable conditions in all the area of the room.

Cassette units - C Series | Multi-Split System
Cassette units - C Series | Multi-Split System

360° circumferential airflow

Effective air distribution

Thanks to the specially designed structure of the decorative panel, the AUX cassette air conditioner can cool every part of the room and provide maximum comfort to all users. Additional outlets in the corners of the panel allow air to be blown in all directions, eliminating the zones with uneven temperature distribution. The circumferential air supply technology provides 360 ° cooled airflow and guarantees effective air-conditioning, even in large rooms.

Built-in drain pump

lifting height up to 120 cm *

As standard, the cassette unit is equipped with a condensate pump which allows to drain water condensate up to 120 cm above the level of the condensate tray.

 

 

* applies to AUX-C-24CAC

Fresh air intake and optimized electrical box

comfort and safety

The cassette unit casing is equipped with specially prepared  opening for fresh air inlet. The device is thus able to supply the room with fresh air. Fresh air intake increases the air quality inside the building, providing health and comfort to people staying in the room. Optimised electrical box offers easy service access and high fire resistance.

Technical data

Model   AUX-C-09CAC AUX-C-12CAC AUX-C-18CAC AUX-C-24CAC
Decorative panel   AUX-P-01 AUX-P-01 AUX-P-01 AUX-P-02
Cooling Efficiency [kW] 2,80 (1,50 - 3,55) 3,52 (1,70 - 3,70) 5,28 (2,50 - 5,60) 7,00 (2,16 - 8,20)
[Btu/h] 9560 (5120 - 12115) 12010 (5800 - 12625) 18015 (8530 - 19107) 24000 (7400 - 28000
Heating efficiency [kW] 3,00 (1,60 - 3,81) 3,81 (2,03 - 4,42) 5,60 (3,03 - 7,03) 8,00 (1,98 - 9,30)
[Btu/h] 10240 (5460 - 13000) 13000 (6930 - 15080) 19107 (10340 - 24000) 27300 (6800 - 31700)
Power supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Power consumption in cooling mode [W] 40 (12 - 68) 40 (12 - 68) 40 (12 - 68) 110 (27,5 - 171)
Power consumption in heating mode [W] 40 (12 - 68) 40 (12 - 68) 40 (12 - 68) 110 (27,5 - 171)
Fan motor power [W] 30 30 30 80
Fan speed (high/mid/low) [rpm] 720/610/530 720/610/530 840/720/660 580/530/470
Air flow (high/mid/low) [m3/h] 700/620/530 700/620/530 760/650/580 1400/1350/1150
Sound pressure level [dB(A)] 42/36/32 42/36/32 45/40/38 47/45/42
Sound power level [dB(A)] 52 52 56 56
Unit dimensions (width x depth x height) [mm] 570 x 570 x 260 570 x 570 x 260 570 x 570 x 260 840x 840 x 246
Panel dimensions [mm] 650 x 650 x 55 650 x 650 x 55 650 x 650 x 55 950 x 950 x 55
Unit weight (net) [kg] 17,0 17,0 17,5 26,0
Panel weight (net) [kg] 2,2 2,2 2,2 5,3
Refrigerant   R32 R32 R32 R32
Pipe fittings
(diameter)
Liquid [mm(inch)] 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4)
Gas [mm(inch)] 12,7 (1/2) 12,7 (1/2) 12,7 (1/2) 15,88 (5/8)
Condensate [mm(inch)] 20 20 20 20
 
 

High-quality inverter compressor

guarantee of energy efficiency and reliability

The inverter rotary compressor of AUX air conditioners guarantees reliable and efficient operation of the devices as well as the highest energy efficiency parameters. It also provides low operating costs and a low level of noise. Durable and high-quality materials of the compressor guarantee its long and failure-free operation.

Cassette units - C Series | Multi-Split System
Cassette units - C Series | Multi-Split System

R32 refrigerant

ecological, highly effective, safe

All AUX air conditioning units of CAC series operate using the newest ecological refrigerant R32, which, comparing to the commonly used R41OA refrigerant, is characterized by higher efficiency and a lower greenhouse effect. It also does not damage the ozone layer.

High energy efficiency

Guarantee of energy-saving operation

Owing to the use of a highly efficient DC inverter compressor, adjustable fan motor and advanced 180 ° sine wave vector control technology, commercial AUX systems achieve high energy efficiency parameters, providing reliable, efficient operation with low energy consumption. All CAC air conditioners are class A ++ in cooling and A + in heating mode.

Cassette units - C Series | Multi-Split System
Cassette units - C Series | Multi-Split System

Szeroki zakres pracy

Reliable operation even in adverse weather conditions

AUX commercial air conditioning systems are characterized by reliable, stable operation even in extreme ambient temperatures. Owing to the use of modern technologies and high-quality components, AUX devices operate in a wide range of outdoor temperatures, i.e. from -15 ° C to 52 ° C in cooling mode and from -20 ° C to 24 ° C in heating mode, providing a high level of comfort in the room in all the seasons of the year.

Anti-corrosion casing of the outdoor unit

Longer life and better aesthetics

The casing of the outdoor unit has been covered with a number of protective layers, protecting it against insects, rodents, moisture, dust and fire. It guarantees a long lifespan of the device and an better aesthetics after many years of exposure to adverse weather conditions.

Cassette units - C Series | Multi-Split System
Cassette units - C Series | Multi-Split System

Intelligent defrosting

Effective operation at low ambient temperatures

The air conditioner activates the defrosting mode only when necessary and only for the time needed to defrost the heat exchanger, which allows the unit to operate almost continuously in heating mode. The intelligent defrosting system used in AUX air conditioners improves the energy efficiency of the devices by 5% and increases the heating efficiency as much as 20% at low ambient temperatures.

Automatic restart

Setting memory in the event of a power failure

In the event of a power failure, the device records the last settings and restarts after resuming the power supply, automatically restoring the previously set operating mode

Cassette units - C Series | Multi-Split System
Cassette units - C Series | Multi-Split System

Outdoor unit drip tray heater

Efficient operation in heating mode

Outdoor units of AUX commercial air conditioner series are equipped with a  drip tray heaters, which allow the devices to operate efficiently in heating mode even in severe frosts, preventing the heat exchanger from icing.

180 sine wave control

Smooth and efficient operation of the compressor

The DC inverter compressor uses 180 ° sine wave control. The solution makes the compressor motor run smoothly and the efficiency increases significantly.

Cassette units - C Series | Multi-Split System
Cassette units - C Series | Multi-Split System

Optimized piping design

Improving cooling capacity

The design provides additional cooling and increases the cooling capacity through separating the refrigerant inlet and outlet.

Features and functions

AUX Air Conditioner functions
R32 refrigerant
AUX Air Conditioner functions
Inverter technology
AUX Air Conditioner functions
Automatic restart
AUX Air Conditioner functions
Hydrophyte aluminum fan vanes
AUX Air Conditioner functions
Intelligent defrosting function
AUX Air Conditioner functions
Fast cooling / heating mode
AUX Air Conditioner functions
Cooling at low temperatures
Washable air filter
Washable air filter
Wireless controller
Wireless controller
AUX Air Conditioner functions
Cooling mode
AUX Air Conditioner functions
Heating mode
klimatyzator aux
Heating at -22oC
AUX Air Conditioner functions
Fan mode
AUX Air Conditioner functions
Drying mode
Auto mode
Auto mode